Floor sensor, room sensor or a combination of the two. Devireg™ 535 is DEVI's latest model of a digital thermostat that contains all three functions in one.
The functional thermostat is well suited for controlling the temperature in the entire house or in selected rooms. Devireg™ 535 controls the heating extremely precisely regardless of whether the thermostat is to control the floor temperature, the room temperature or a combination of the two.
It has developed a system called the Electronic Thermal Compensator or just ETC. Devireg 535 is the first ETC programmed thermostat. This means that the thermostat can keep to the temperature required, regardless of the size of the room.
Devireg 535 is pre-programmed with three programmes which match most people's need for heating control. The development department at DEVI has been working intensively with the development of a simple and user-friendly design which makes it easy to change the temperature as well as the time. This means that it is always possible to adjust the thermostat as the need for heat changes.
Comes complete with child lock safety function.
Devireg 535 is the thermostat with the market's lowest standby consumption of just 0.3W.
As the world’s leading manufacturer of electrical floor heating systems, DEVI guarantees quality. Devireg 535 is equipped with a two-pole safety switch, which interrupts the thermostat 100%. At the same time, DEVI’s Sensor Failure Monitoring safety system ensures that the floor heating is immediately interrupted if the sensor is interrupted or short-circuited.
Product Specifications:
- Voltage: 180-250 V ˜ 50/60 Hz.
- Standby Power Consumption: max 0.30W.
- Resistive Load: 230V ˜15A / 3450W.
- Inductive Load: cosφ = 0.3 Max. 4A.
- Sensing Unit: NTC 15kOhm at 25°C.
- Room Sensor: +/-0.2°C.
- Floor Sensor Only: +/-0.4°C.
- Ambient Temperature: -10°C to +30°C.
- Frost Protection: 5°C.
- Room and Floor Sensors Combines: Floor max. 20–50°C, Floor min. 10–45°C.
- Sensor Failure Monitoring: Built–in monitoring circuit, switches off heating if sensor is disconnected or short–circuited.
- No Light: System Off.
- System standing by, set point temperature reached.
- Green Light Flashing: Floor sensor is defective.
- Red Light: System is heating.
- Switching Between Red and Green Light: Floor temperature limit prevents the set point room temperature from being reached.
- IP Class: IP31.
- Dimensions (mm): 85(W) x 85(H) x 21(D).
More about the Devimat underfloor heating systems