Guide to IP Ratings & GUIDANCE ON BATHROOM LIGhTING SPECIFICATION
IP =
Ingress Protection. The IP rating classifies the degree of protection from
dust and moisture and is recognized in most European countries.
An
example of IP rating is IP54 where the first digit (5) relates to the
ingress of dust and the second digit (4) relates to the ingress of moisture.
FIRST
DIGIT IP?X
|
IP
- |
Degree of protection against dustI |
|
0 |
No
protection |
|
1 |
Protected against solid objects greater than 50mm diameter, eg hand |
|
2 |
Protected against solid objects greater than 12mm diameter, eg fingers |
|
3 |
Protected against solid objects greater than 2.5mm diameter, eg tools
and thick wires |
|
4 |
Protected against solid objects greater than 1mm diameter, eg thin wire |
|
5 |
Protected against limited ingress of dust, eg no interference in
operation of unit |
|
6 |
Protected against any ingress of dust |
SECOND
DIGIT IPX?
|
IP-X |
Degree of protection against moisture |
|
0 |
No
protection |
|
1 |
Protected against vertically dripping water |
|
2 |
Protected against vertically dripping water and up to 15 degrees from
vertical |
|
3 |
Protected against spraying water up to 60 degrees from vertical |
|
4 |
Protected against splashing water from any direction |
|
5 |
Protected against jets of water from any direction |
|
6 |
Protected from powerful jets of water with limited ingress with no
harmful effect |
|
7 |
Protected against total immersion in water for limited periods |
|
8
|
Protected against total immersion in water under pressure for an
indefinite period. |
SPECIFICATION OF BATHROOM
FITTINGS
|
ZONE |
LOCATION (See
Below) |
RESTRICTIONS (See
Above for IP ratings) |
|
0 |
The interior of the
bath tub or shower basin |
Only SELV not
exceeding 12v AC nominal voltage. Transformers must be sited outside
Zones 0,1,2. IP rating must be at IPX7 |
|
1 |
Area immediately
above bath or shower tray |
IP rating of at
least IPX4.
Where water jets are likely to be used for cleaning purposes in
communal baths & showers at least IPX5 is required |
|
2 |
Within 0.6m of the
outside edge of the bath or shower |
IP rating of at
least IPX4.
Where water jets are likely to be used for cleaning purposes in
communal baths & showers at least IPX5 is required |
|
3 |
Anywhere outside
Zones 0,1,2 |
No specific IP
rating unless where water jets are likely to be used for cleaning
purposes in communal baths & showers at least IPX5 is required |

|