advanced search
Lights
Dimming Systems
Switches and Sockets
Electrical Items
Heating and Ventilation
Fire and Security
Fire Protection Downlights
Fire Alarms
Wireless Intruder Alarms
Intruder Alarms(hard wired)
Lighting PIR
Door entry monitoring
Digital CCTV Surveillance
Energy management
Photocell
Timers & Thermostats
Time Lag Switches
Occupancy Detectors & Switches
Home
>
Fire and Security
>
Energy management
>
Time Lag Switches
> Time Lag Switch - touch activated time lag switches
Click on image to zoom in
enlarge image in popup
£26.84
(ex VAT)
Model:
KH2
(Exceptions and Terms &
Conditions apply.
View
.)
Time Lag Switch - touch activated time lag switches
Touch activated time lag switches to replace existing light switches.
UK Patented No. 2217933
Touch activated time lag switch
Load Rating at 230VAC: Incandescent / Fluorescent / Compact Fluorescent - 10A
Time Delay: 10 secs - 20 min approx.
The KH2 time lag switches are a quick and effective way to reduce energy consumption for lighting applications. Pressing the button or touch pad brings the lights on; the lights will then switch off automatically after a preset time period has elapsed.
These units do not require a neutral connection, therefore they can be used to replace an existing light switch. The duration of the time delay is set by a thumbwheel on the reverse of the unit.
Time lag switches can be used in two way and intermediate switching arrangements without any extra wiring.
Features:
LOAD: 10A of lighting including incandescent, fluorescent, compact fluorescent, low voltage (switch primary of transformer).
Fluorescent and compact fluorescent fittings with “switch start” ballasts - 10 ballasts maximum.
Power factor correction capacitors must be fitted.
Most fluorescent fittings have power factor correction capacitors fitted. If they are not present the unit may fail to turn off properly or flicker. In this case fit one capacitor per circuit with a minimum value of 1μF for every unit installed. The capacitor should be fitted across switched live and neutral. Note that it is not necessary to fit a capacitor on every fitting. This also applies to fittings controlled with high frequency ballasts and maintained emergency fittings.
Not suitable for switching contactors
Not suitable for SON lighting
Not suitable for heating or ventilation loads.
SUPPLY VOLTAGE 220-240 Volts AC 50 Hz
TIME OUT PERIOD 20 seconds to 20 minutes (approximate)
FIXING METHOD Surface fixing 25mm deep plastic surface mount moulded box.
Flush fixing 25mm steel wall box or 32mm deep cavity wall box.
TERMINAL CAPACITY 1.5mm2
MATERIAL Flame retardant ABS
TYPE Class 2
TEMPERATURE -10°C to 35°C
CONFORMITY EMC-89/336/EEC
LVD-73/23/EEC
Wiring scheme and instructions
for this time lag switch - pdf file.
Further information about this item
.
VAT:
ON
/ OFF
Your cart is empty.
Write a review on this product »
Email:
Tell someone you know about this product.
Payments powered and secured by
Contact Us
|
Vacancies
|
Site Map
|
Privacy Notice
|
Terms and Conditions
Ceiling Lights
|
Metal Flat Plate Sockets
|
Fire Detectors
|
1stSparks
Lights Deals
|
Magnetic downlight
|
Switches&Sockets
|
Wireless Alarm Kit
Web Production
|
Resources
|
SparksDirect Twitter
Copyright © 2003-2010
SparksDirect