Sale Icon
Review Icon
Free Delivery Icon
Fike Twinflex Pro 2 Zone Fire Alarm Panel Rafiki 505-0002 with Multipoint Detection

Fike Twinflex Pro 2 Zone Fire Alarm Panel Rafiki 505-0002 with Multipoint Detection

This is the Fike Twinflex 505-0002 Twinflex Pro 2 Zone Panel. Please note: this panel comes without ..

Model: 5050002

£175.57 Ex. VAT

Fike Twinflex Pro 4 Zone Fire Alarm Control Panel, 4 Zone Control Panel Rafiki 505 0004 2-wire

Fike Twinflex Pro 4 Zone Fire Alarm Control Panel, 4 Zone Control Panel Rafiki 505 0004 2-wire

This is the Fike Twinflex Pro 4 Zone Fire Alarm Panel - model no. Fike 505 0004 (the manufacturer is..

Model: 5050004

£211.24 Ex. VAT

Fike Twinflex Pro 8 Zone Fire Alarm Control Panel for Conventional 2-Wire Fire Alarm System

Fike Twinflex Pro 8 Zone Fire Alarm Control Panel for Conventional 2-Wire Fire Alarm System

This is the Fike Twinflex Pro eight zone fire alarm panel (panel only), an intelligent analogue non-..

Model: 5050008

£272.21 Ex. VAT

Fike Twinflex Pro 4 Zone Expansion Card

Fike Twinflex Pro 4 Zone Expansion Card

This is the Fike Twinflex Pro 4 Zone Expansion Card..

Model: 5050006

£98.05 Ex. VAT

Fike Twinflex Pro OSP PC Programming Software

Fike Twinflex Pro OSP PC Programming Software

This is the Fike Twinflex Pro software for installing on the PC...

Model: 5050040

£35.93 Ex. VAT

Fike TwinflexPro2 Repeater Panel 505-0010 allowing System Status and Control at a Remote Location

Fike TwinflexPro2 Repeater Panel 505-0010 allowing System Status and Control at a Remote Location

This is the Fike TwinflexPro2 Repeater Panel - Fike 505-0010, a smaller panel than the TwinflexPro2 ..

Model: 5050010

£139.85 Ex. VAT

Fike Twinflex Hatari Sounder in Red, Rafiki 302 0001 Red Sounder

Fike Twinflex Hatari Sounder in Red, Rafiki 302 0001 Red Sounder

This is the Fike Twinflex Hatari Sounder in Red. Twinflex Hatari sounders for higher sound outp..

Model: 3020001

£18.47 Ex. VAT

Fike 402 0006 Twinflex Manual Call Point with a Resettable Plastic Element for 2 Wire Fire Alarm System

Fike 402 0006 Twinflex Manual Call Point with a Resettable Plastic Element for 2 Wire Fire Alarm System

This is the Fike 402 0006 Twinflex Manual Call Point for 2 Wire Fire Alarm System with a Resettable ..

Model: 4020002

£16.93 Ex. VAT

Fike Low Profile Strobe Sounder, Rafiki Twinflex Flash Point 302 0012

Fike Low Profile Strobe Sounder, Rafiki Twinflex Flash Point 302 0012

This is the Fike Low Profile strobe sounder - Twinflex Flash point, Rafiki 3020012 Fike Low Pro..

Model: 3020012

£28.98 Ex. VAT

Fike Sita Manual Call Point Addressable, Rafiki Sita 403-0002 Plus Call Point

Fike Sita Manual Call Point Addressable, Rafiki Sita 403-0002 Plus Call Point

This is the Fike Sita 200 Plus Manual Call Point - manufacturer code: Rafiki 403-0002. Note: th..

Model: 4030002

£28.05 Ex. VAT

Fike Sita Multipoint Detector, Addressable Rafiki 205 0003 Smoke and Heat Detector No Sounder

Fike Sita Multipoint Detector, Addressable Rafiki 205 0003 Smoke and Heat Detector No Sounder

This is the Fike 205 0003 Twinflex Multipoint ASD Detector, Rafiki 205-0003 with No sounder. Note: ..

Model: 2050003

£25.67 Ex. VAT

Fike Sita Multipoint Detector with Sounder, Rafiki 205 0001 ASD Smoke and Heat Detector

Fike Sita Multipoint Detector with Sounder, Rafiki 205 0001 ASD Smoke and Heat Detector

This is the Fike Twinflex Multipoint ASD Detector, Rafiki 205-0001 heat and smoke detector with Soun..

Model: 2050001

£39.21 Ex. VAT

Fike Twinflex Output Module, Rafiki 802 0001 Fire Alarm Output Module

Fike Twinflex Output Module, Rafiki 802 0001 Fire Alarm Output Module

This is the Fike Twinflex Output Module, Rafiki 802 0001 Fire Alarm Output Module available at Spark..

Model: 8020001

£46.65 Ex. VAT

Fike Twinflex Pro Panel Control Key 09-0026, Spare Panel Enable Key for Twinflex Pro Fire Panel

Fike Twinflex Pro Panel Control Key 09-0026, Spare Panel Enable Key for Twinflex Pro Fire Panel

This is the 09-0026 Fike Twinflex Pro Panel Key, a spare or replacement panel enable key for the Raf..

Model: 090026

£3.79 Ex. VAT

Twinflex 25-0083-303 Manual Call Point Protective Cover, Transparent Plastic Cover

Twinflex 25-0083-303 Manual Call Point Protective Cover, Transparent Plastic Cover

This is the Twinflex 25-0083-303 Manual Call Point Protective Cover, a Transparent Plastic cover fla..

Model: 25008330

£4.16 Ex. VAT

Fike Spare Battery Lead Connectors and Resistors / Spare Fuses for Fike Twinflexpro Panels

Fike Spare Battery Lead Connectors and Resistors / Spare Fuses for Fike Twinflexpro Panels

This is a replacement "goody bag" for the TwinflexPro Panels containing spare fuses, battery connect..

Model: FIKESPAR

£16.42 Ex. VAT

Showing 17 to 32 of 32 (2 Pages)

Related Articles

Fike Twinflex Pro2: a Reliable Fire Protection System you can Count on

At Sparks, we distribute a wide range of fire protection systems, and in particular Fike Twinflex Pro is a reliable fire protection system you can count on. Many say that a conventional 2-wire fire alarm system is often the natural choice for smaller applications or where budget constraints exist.Continue reading this guide to find out about:Fike Twinflex Pro2 - applications and featuresFike Twinflex Pro2 - panels and accessoriesThe Twinflex Multipoint ASD Detector - FeaturesThe Twinflex Multipoint ASD Detector - Detection ModesFike Twinflex Pro2 - Alarm Confirmation FeatureTwinflex Pro2 Detectors and Accessories Fike’s TWINFLEXpro2 2-wire fire alarm system has long been known for its adaptability and cost-effectiveness within a variety of applications, big or small, making it one of the most flexible products on the market. Fike Twinflex Pro2: a Reliable Fire Protection System you can Count onWhy do we say this? This versatile fire alarm system from Fike incorporates the Twinflex Multipoint ASD using smoke and heat detection with an optional built-in sounder, allowing the whole system to be installed using only one pair of wires per zone. That means easier, faster installations and cost savings. Building on those strengths and designed for ease of use and state-of-the-art monitoring, the LPCB-approved TwinflexPro2 is the next generation in 2-wire fire alarm reliability.Fike Twinflex Pro2: Applications and FeaturesSome of the most popular applications for the versatile Fike Twinflex Pro2 conventional fire protection system are:SchoolsNursing HomesBed and breakfastRestaurantsRetail StoresMuseumsOffice BuildingsHere are the features of the Fike Twinflex Pro2 system:Allows detectors and sounders to be installed on the same pair of wiresDifferentiates between call point or detector alarms4-line x 20-character LCD displayCheckpoint alarm verification featureAvailable in 2, 4, and 8 zone panel versionsHighlighted selection menuEvent log storing up to 500 eventsUp to 32 devices per zone3 enhanced test modesBuilt-in EOL capability in all devicesZone can be configured to day/night detection modePanel design changes to allow easier installation4 & 8 zone panels can now be configured to accept conventional devices on zones 5 to 8 with the optional conventional zone cardProtective cover to stop accidental damage when installingOptional extended battery box with capacity for 2 x 12V 7.0Ah batteriesFike Twinflex Pro2 - Panels and AccessoriesHere is the full list of Fike Twinflex Pro2 panels and accessories:TwinflexPro² 2 Zone Control Panel (Fike 505-0002)Intelligent 2-wire control panel with 2 zones suitable for Twinflex devices. Dual-purpose flush and surface housing. Requires 2 x 12V 3.2Ah Sealed Lead Acid Batteries (not included).TwinflexPro² 4 Zone Control Panel (Fike 505-0004)Intelligent 2-wire control panel with 4 zones suitable for Twinflex devices. Dual-purpose flush and surface housing. Requires 2 x 12V 3.2Ah Sealed Lead Acid Batteries (not included).TwinflexPro² 8 Zone Control Panel (Fike 505-0008)Intelligent 2-wire control panel with 8 zones suitable for Twinflex devices. Dual-purpose flush and surface housing. Requires 2 x 12V 3.2Ah Sealed Lead Acid Batteries (not included).TwinflexPro² Repeater Panel (Fike 505-0010)The repeater will only work with the 4 & 8 Zone Twinflex Pro2 panels using version 2.0 software onwards.TwinflexPro2 Boxed Kit (Fike 604-0002)1 x TwinflexPro2 Zone Panel, 7 x Twinflex Multipoint ASD with sounder, 2 x Twinflex Manual Call Point c/w covers, 1 x Head Removal Tool.TwinflexPro2 Boxed Kit (Fike 604-0004)1 x TwinflexPro2 4 Zone Panel, 7 x Twinflex Multipoint ASD with sounder, 2 x Twinflex Manual Call Point c/w covers, 1 x Head Removal Tool.TwinflexPro2 Boxed Kit (Fike 604-0008)1 x TwinflexPro2 8 Zone Panel, 7 x Twinflex Multipoint ASD with sounder, 2 x Twinflex Manual Call Point c/w covers.TwinflexPro² 4 Zone Expansion Card (Fike 505-0006)Can only be used with 505-0004 4 zone Twinflex Pro panel & Twinflex Pro 2TwinflexPro² Conventional Expansion Card (Fike 505-0007)Can only be used with 4 zones & 8 Zone TwinflexPro2 panels.TwinflexPro² Battery Conversion Kit (Fike 505-0020)Holds 2 x 7Ah batteries allowing for additional standby capacity of up to 72 hours.TwinflexPro OSP (Fike 505-0040)PC programming software for all TwinflexPro panels; Requires a USB-A to USB-B interface lead (not supplied).Buy TwinflexPRO by FikeThe Twinflex Multipoint ASD Detector - FeaturesUsing the Twinflex Multipoint ASD as part of the TWINFLEXpro² system means that when a detector is wired to the system, a sounder and strobe can also be connected without extra installation time or cost. This greatly reduces the number of points that need to be installed and the time it takes to install.As the Twinflex Multipoint ASD offers 7 different modes of detection, the installation is made even simpler since one device suits all applications.Whatever type of detection is required, it can be selected by the flick of a switch at the time of commissioning 3 different smoke modes, 2 fixed temperature heat modes, a rate of rise mode and a combination smoke or heat mode. The Twinflex Multipoint ASD is available with or without a full specification integral 90dBA sounder no extra devices need to be purchased when an audible warning is required. If extra sound is required or for areas that do not require detection, then a choice of several different standalone sounders or sounder beacons can be used on the same two wiresThe Twinflex Multipoint ASD Detector - Detection ModesTwo-wire installation - only one circuit per zone to connect detectors and sounders - installation savings can be as high as 40%. There are 7 modes of detection.The Twinflex Multipoint ASD saves the cost of a sounder. Warning of head contamination, before going into false alarm. Easily removable for maintenance at height. The Twinflex Multipoint ASD Detector detection modes are:Smoke 1: Used where ionization detectors are normally fitted, especially when there are high ceilings or a risk of free-burning fires (chemical stores etc), or fires that need to be detected extremely quickly.Smoke 2: Used where optical detectors are normally fitted, when there is a risk of a smouldering fire and for escape routes.Smoke 3: Designed for use in areas that are prone to nuisance alarms. The reduced sensitivity linked with a time delay feature means that a higher concentration of smoke needs to be present for a constant time period before a fire decision is made.Heat 1: (Rate-of-Rise) – Used where a standard rate-of-rise detector would normally be used.Heat 2: (Standard Fixed Temperature – 58°C /136°F approximately) – A standard fixed temperature heat detector, suitable for domestic kitchens, etc.Heat 3: (High Fixed Temperature – 90°C / 194°F approximately) – High fixed temperature heat detector suitable for boiler rooms, commercial kitchens, etc.Fike Twinflex Pro2 - Alarm Confirmation FeatureEarly warning fire alarm verification is often crucial. The disruption to business and costs associated with responding to false alarms can be enormous. The TwinflexPro2 offers alarm confirmation technology, which can help eliminate nuisance or false alarms.Using the built-in alarm confirmation feature, until an alarm has been confirmed within an individual area, only that area is evacuated. At the same time, if an alarm is triggered in a common area, the device initiates a full alarm evacuating all surrounding areas. This unique panel feature is vital where two-stage alarms are required.For example - when an alarm is indicated by an individual detector, the sounder for that device/zone is activated and the control panel carries out the configured number of confirmation checks on that specific zone.If the alarm is confirmed, the control panel enters the fire state and all additional notification devices are activated throughout the facility. If the detector alarm is rejected, the sounders on the zone are silenced, and the detector in alarm is reset.For safety, activating a call point will override any delays or confirmation settings.Twinflex Pro2 Detectors and AccessoriesHere are the Twinflex Pro2 Detectors and Accessories - many of which can be found on our website for purchase.Twinflex Multipoint ASD Detector (Fike 204-0003)A multifunction smoke and heat detector with three smoke detection modes, three heat detection modes and one combination mode. Built in ‘End of Line’. These options are set by the DIL switch. Supplied complete with mounting base and dust cover.Twinflex Multipoint ASD Detector with Sounder (Fike 204-0001)As above but complete with an inbuilt sounder featuring three sound patterns and two volume levels.Twinflex Multipoint ASD Detector with Sounder/Strobe (Fike 204-0012)As above but complete with an inbuilt sounder/strobe featuring three sound patterns and two volume levels and an LED strobe array. Visual indicator strobe.Twinflex Manual Call Point (Fike 406-0006)Manual call point with resettable element reset key, back box, adaptor plate for flush mount and inbuilt ‘End of Line’ set by DIL switch (includes call point cover).Twinflex Manual Call Point Weatherproof (Fike 406-0007)IP65 weatherproof manual call point with resettable element, reset key, back box and inbuilt ‘End of Line’ set by DIL switch (includes call point cover).Twinflex Hatari Sounder: Red/White (Fike 302-0001 + 302-0002)Sounder with 97dB adjustable output and inbuilt ‘End of Line’ set by DIL switch. Supplied complete with mounting base.Twinflex Sound Point: Red/White (Fike 313-0021 + 313-0022)Sounder with 85dB output, three sound patterns and inbuilt ‘End of Line’ set by DIL switch. Supplied complete with back box and flush adaptor plate.Twinflex Hi Point (Fike 302-0004)IP55 Internal / External horn sounder with 90dB output, three sound patterns and inbuilt ‘End of Line’ set by DIL switch. Supplied complete with back box and flush adaptor plate. Suitable for indoor and outdoor applications.Twinflex Flash Point (Fike 302-0012)Low profile sounder and LED visual indication beacon with 90dB output, three sound patterns and inbuilt ‘End of Line’ set by DIL switch. Supplied complete with mounting base. Twinflex Flash Point: Domed (Fike 302-0022)Sounder and LED visual indication beacon with 90dB output, three sound patterns and inbuilt ‘End of Line’ set by DIL switch. Supplied complete with mounting base.Twinflex Flash Point: Weatherproof (Fike 302-0023)IP52 LED visual indication beacon with inbuilt ‘End of Line’ set by DIL switch. Supplied complete with mounting base (note, this item does not include a sounder, i.e. beacon only).Twinflex Input / Output Module (Fike 802-0006)Relay interfacing module including two sets of 2A-rated SPCO relay contacts, one monitored input and inbuilt ‘End of Line’.ASD Head Removal Tool (Fike 25-0046-201)To remove the optical chamber of Multipoint ASD detectors. The tool may be mounted onto a pole for high-level access. This tool fits directly onto the solo poles range of detector test equipment.Buy Twinflex Multipoint DetectorsMany of the sounders and panels in the Fike Twinflex Pro2 range are available at Sparks via, Conventional Fire Alarms. For any further information, do not hesitate to contact us. The above is inspired by a guide from Fike on their Fike Twinflex Pro2. The Fike Twinflex Pro2 is a Reliable Fire Protection System you can Count on.

Rafiki Multipoint Sita for the Sita 200 plus System, high technology fire detectors

The specifiers and the installers who choose the Multipoint detector do so secure in the knowledge that the fire detection performance of the detector can be matched to the environment in which it is installed –and changed at any time during the lifetime of the installation. With the Sita 200 plus System, a high technology approach has been adopted, with a microcomputer in each detector implementing a large degree of distributed intelligence. The system can support 200 Multipoint combined detectors/sounders on a single loop. Each one not only provides detection but also the option of a built-in sounder. Integrity of the system is maintained by way of a built-in isolator in each device. The Rafiki Sita system intelligence has been harnessed in such a way that the equipment used is very easy to install, commission, and maintain. The system has been designed to high specification and quality standards and is intended to fully comply with the new EN54 -2 and EN54 - 4 standards and EU directives. Rafiki Multipoint Sita - Main Features Fast short circuit isolator in every device; 15 combinations of smoke & heat detection modes; Multi-stage alarms - pre-alarm feature; 7 sound patterns - plus off, 3 different volume settings – if using Sita Multipoint with integral sounder; Auxiliary digital inputs and outputs are available at any Addressable Multipoint device; Automatic continuous self-calibration; Addressable Multipoint detector is monitored for all failures of the sensor chamber - a warning is indicated when a smoke detector head requires servicing; Maintenance is made easy with the unique disposable optical chamber, designed as a cost-effective solution to cleaning and re-calibration; All modes are compliant with European detector-type specifications, and are suitable for use in installations compliant with BS5839: Part 1: 2002; More details about the Rafiki Multipoint: eliminate the false alarms; more on the Rafiki detectors; The Multipoint Detector; new Multipoint ASD detectors, and the modes of detection. Rafiki Multipoint Sita - Modes of detection SMOKE 1: Highly thermally enhanced optical Used where ionization detectors are normally fitted, especially when there are high ceilings or risk of free-burning fires SMOKE 2: Thermally enhanced optical Used where optical detectors are normally fitted, when there is a risk of a smoldering fire and for escape routes. SMOKE 3: Thermally enhanced optical with pulse rejection Used where optical detectors are normally used in positions exposed to brief concentrations of water vapor or smoke e.g. from a bathroom, kettle etc. HEAT 1: Rate of rise to 58°C Used where a standard rate of rise detector would normally be used HEAT 2: Low fixed temperature 58°C Used where a standard fixed temperature heat detector would normally be fitted, suitable for kitchens, etc HEAT 3: High fixed temperature 90°C Used where a high fixed temperature heat detector would normally be fitted, suitable for boiler rooms, etc. Combinations Any combination of smoke and heat modes may be selected, and differing alarm responses selected for each mode. If the Multipoint with an integral sounder is required, then it too can be set to a choice of 7 different sound patternsBuy Fike Fire Detectors at Sparks

Rafiki Multipoint ASD detectors, the automatic calibration and the modes of detection

This article is the continuation of the, new Multipoint ASD detectors from Rafiki(short introduction) previously posted on our blog. Via this article you can find out more about the automatic calibration and the modes of detection offered by the Rafiki MultiPoint detectors (heat and smoke detection modes). All modes are compliant with European detector type specifications, and are suitable for use in installations compliant with BS5839: Part 1: 2002, Part 6 2004 if used in conjunction with a "Twinflex Plus" system. The Twinflex Intelligent conventional detector can be set to any one of the smoke or heat detection modes as well as a Combined Mode (Smoke 2 & Heat 2) where a smoke or heat source can trigger a fire decision. This means the end user is given optimum fire protection, even if the installer is unsure of the use of the particular area where the detector is sited. As part of the Twinflex system, all the Twinflex products including the Twinflex Multipoint detector feature an End of Line monitoring switch, which negates the need to install End of Line monitoring resistors. The Sita Intelligent addressable detector is able to offer all the choices for detection or a combination of any listed to give a choice of up to 15 different settings. It is set via a PC when programming the system. The Sita Multipoint also has an in-built loop isolator as well as an input/output facility for local control and switching. The Multipoint Detector also has the unique benefit of an optional full-specification integral sounder. A 90dBA output can be achieved. The Twinflex Intelligent two-wire detector can be set to 3 different sound patterns, as well as switched off, with 2 sound output levels. The Sita Intelligent addressable detector has 7 different sound patterns and 3 volume settings. Automatic Calibration To ensure the detection capabilities of the Multipoint are never compromised it self-calibrates every 6 hours. It continuously monitors for dust contamination, until, over a period of time, depending on the environment, it reaches a point where the chamber becomes saturated. Before this can develop into a false alarm situation, the panel will indicate that a Multipoint needs attention on both the Twinflex and Sita systems. To make maintenance easy, the Multipoint features a disposable optical chamber. This means the chamber can be simply thrown away, and replaced economically when necessary. Rafiki Multipoint Reflected Optical Value The Rafiki MultiPoint detector - modes of detection Smoke 1: Used where ionization detectors are normally fitted especially when there are high ceilings or risk of free burning fires (chemical stores etc), or fires that need to be detected extremely quickly. Smoke 2: Used where optical detectors are normally fitted when there is a risk of a smoldering fire and for escape routes. Smoke 3: This setting is designed for use in areas that are prone to nuisance alarms. The reduced sensitivity linked with a time delay feature means that a higher concentration of smoke needs to be present for a constant time period, before a fire decision is made (Fig 1). This setting, for example, is ideal for hotel bedrooms with ensuite shower rooms, the end user can change the setting from smoke 2 to smoke 3 if nuisance alarms are becoming a problem – whilst still offering optimum protection of a smoke detection setting, especially if this is what has been specified. Heat 1: (Rate of Rise) Used where a standard rate of rise detector would normally be used Heat 2: (Standard Fixed Temperature - 58ºC approx) Used where a standard fixed temperature heat detector would normally be fitted, suitable for kitchens etc Heat 3: (High Fixed Temperature - 90ºC approx) Used where a high fixed temperature heat detector would normally be fitted, suitable for boiler rooms etc. You can read the previous article concerning the new Multipoint ASD detectors from Rafiki - or visit the Rafiki conventional fire alarms section on our website for more models and details. Most of the above specs are taken from the Rafiki Technical Sheet on, The New Multipoint ASD detector from Rafiki.Buy Fike Conventional Fire Alarms

new Multipoint ASD detectors from Rafiki - the Rafiki conventional fire alarms

The Rafiki's Multipoint ASD detector range have broken new barriers in fire detection and alarm. Not only does the multipoint offer seven modes of fire detection it also offers an optional built-in sounder and a sounder strobe in a single device. The Rafiki multipoint uses patented advanced optical scatter sensor design along with sophisticated electronic technology to deliver reliable smoke or heat detection, whilst substantially reducing false alarms. The Multipoint ASD retains all the advantages of the original Multipoint detector with a range of additional features to make it a truly market-leading design. "Stealth" Optical Chamber Design The method of optical scatter fire detection is well known. Sensors comprise an optical emitter and a receiver positioned in a sensing chamber. The emitter and receiver are positioned such that there is no line of sight between them, although some light from the emitter does reflect on the walls of the chamber and into the receiver; this is known as standing scatter level. When smoke enters the chamber it increases radiation from the emitter and substantially increases the radiation detected by the receiver, a sensor circuit then triggers an alarm. A disadvantage of this design is that dust, grease etc. enters the chamber and settles on the walls causing the scatter level to increase or decrease depending on the type of contamination. This variation can cause false alarms or can mask the presence of a true alarm condition. Stealth Chamber Rafiki has designed a patented optical scatter smoke sensor that alleviates this problem. This has been achieved by creating a secondary chamber that collects the contamination out of site of the emitter and receiver thereby substantially reducing the incidence of false alarms and improving detection reliability. Multi-Criteria Detector The Rafiki "Multipoint" detector has set new standards in detector technology, using microprocessor control, offering the installer a full range of detection capabilities with audible and visual warning in one compact device. Specifiers and installers who choose the Multipoint detector, do so secure in the knowledge that the fire detection performance of the detector can be matched to the environment in which it is installed – and changed at any time during the lifetime of the installation. The mode of detection required can be simply changed by way of a DIL switch in the detector (configurable via commissioning software on addressable systems). Some of the Rafiki Multipoint Detectors - from the Sita Range - newly added to the website are: Rafiki 205 0001 - Rafiki Sita Multipoint Detector with Sounder, ASD smoke and heat detector, Rafiki 205 0003 - Rafiki Sita Multipoint Detector Addressable, smoke and heat Detector no sounder P Rafiki 302 0012 - Rafiki low profile strobe sounder, Rafiki Twinflex Flash Point (Low Profile)Buy Fike Multipoint Detectors