This is the Aico Ei146e Optical Smoke Alarm Mains Powered with RadioLink, 9V Alkaline Battery Back-up and Easi-fit Base available at Sparks. The Ei146e Optical Smoke Alarm is a mains powered unit and can be interlinked with other Aico alarms through either a hard wired or wireless interconnection when you purchase the Ei168RC RadioLINK base.
Please note: this item is non-returnable; due to the nature of this item, it has an electronic component and sensor, and we cannot take this item back for a refund as "unwanted".
Aico Ei146e Optical Smoke Alarm is a mains-powered alarm with a 9V Alkaline battery back-up and contains a large, proven optical smoke chamber.

Aico Ei146e Optical Smoke Alarm Mains Powered - Features

  • As this alarm contains a 9V Alkaline battery back-up, this battery will need changing over the course of its 10-year life. It has a 10-year warranty from the year of manufacture, not from the year of purchase.
  • Alarm Siting: Different alarms sensors work best at detecting different types of fire and so should be sited in appropriate rooms throughout a property. Optical alarms are best at detecting slow, smouldering fire which are commonly caused by sofas or electrical fires.
  • The Aico Ei146e optical smoke alarm is suitable for: Hallways, Landing, Livings Room, Dining Room, Bedroom
  • By fitting an Optical alarm in these areas, you are less likely to get nuisance alarms, especially if the alarm is located close to the Kitchen.
  • Easi-fit base: The alarm is supplied with an easi-fit base to make it quick and simple to install.
  • RadioLINK Technology: As with the rest of the Aico 140e Series alarms the Aico Ei146e Optical alarm can be interconnected with other alarms and accessories through hard wire connection or, for less mess and disruption, by RadioLINK wireless interconnection. To be interconnected via RadioLINK, you need to purchase the Ei168RC separately.

Aico Ei146e Optical Smoke Alarm Mains Powered - Specs

  • Sensor Type: Optical.
  • Supply Voltage: 230V AC, 50Hz.
  • Battery Back-up: 9V Alkaline Replaceable.
  • Indicators: Green – Power / Red – Alarm or fault
  • Power Consumption (W): 0.75
  • Sound Level: 85dB(A) at 3m.
  • Operating Temperature: -10°C to 40°C.
  • Humidity Range: 15% to 95% relative humidity.
  • Button Test: Simulates the effect of smoke and checks chamber, electronics and horn.
  • Self Test: Smoke chamber is automatically tested every 40 seconds and unit beeps (without red LED flash) if it is degraded.
  • Insect Screen: Prevents insects or debris entering chamber (1.00mm mesh size).
  • Plastic Material: UL94VO flame retardant.
  • Dimensions – Product: 148mm x 148mm x 47mm
  • Weight: 345g (product only), 389g (boxed)
  • Guarantee: 5 years
  • Approvals: BS EN 14604:2005.
  • Visual indicators: Green LED – Power supply Red LED – Self-test, alarm (if coincides with horn sounding), hush mode, memory or fault
  • Alarm Sounder: Piezoelectric Horn
  • Alarm Sound Level: 85dB(A) at 3 meters (min)
  • Interconnection: Up to 12 units can be interconnected via a hardwired or wireless system (using optional Ei168RC mounting plate)
  • Fixings: Supplied with Easi-fit anti-tamper mounting plate with integral terminal block and wiring cover, includes screws and wall plugs

Note: Some images and pictures are for reference only. The item may differ from the image/picture due to manufacturer's change. Should you require the exact item in the picture, please call or email us to enquire.

Need more detailed specs?

Ask a question

Note: HTML is not translated!

Aico Alarms Fault Finding - 10 Questions and Answers, Aico Heat, Smoke, CO Alarms

As with most technology, you may experience technical faults with Aico’s range of alarms. Aico has a helpful page for basic fire alarm and cleaning maintenance advice. This Sparks guide goes into more depth concerning Aico alarms fault-finding. We will advise you on how to resolve various issues that may arise, and ten of these questions we try to answer are: Why is my smoke or heat alarm sounding for no reason? Why is there a regular single beep coming from my smoke or heat alarm? Why is there an irregular beep coming from my smoke or heat alarm? Why aren’t my alarms interconnecting via RadioLink+ interconnect? Why aren’t my alarms interconnecting via hard-wired interconnect? How do I fix the test button, if it isn’t working? Why aren’t alarm accessories working with all or some alarms? Why is my Carbon Monoxide (CO) alarm sounding? Why is my Carbon monoxide alarm giving a regular single beep? Why is my CO alarm beeping irregularly? Why is my smoke or heat alarm sounding for no reason? Identify the alarm with the flashing red light. Press the ‘Hush’ button to silence it. If this doesn’t work, clean the alarm using a vacuum. Wait for 10 minutes and the problem should be resolved. After dealing with the errant alarm, take the following steps: If using RadioLINK+, ensure that the alarms have been properly House-Coded. Reset and House-Code the RadioLINK+ system. Check that any old hard-wire interconnection wires have been disposed of. See if there are any cooking fumes or steam around the alarm in question. If this is the case, it may be situated incorrectly for the alarm type. Look into where your alarm should be placed. Sparks sells Aico’s Ei3014 heat alarm, Ei3016 optical smoke alarm, as well as other heat and smoke alarms. We also suggest you read more about the recommended sites for locating these alarms. Why is there a regular single beep coming from my smoke or heat alarm? If the green power light is off, check your fuses and wiring. If the alarm is a 140RC Series, detach the alarm from its base and change the battery. Why is there an irregular beep coming from my smoke or heat alarm? Check the wiring (and connection) of the alarm. Find any gaps where cables enter the base of the alarm. Fill in these gaps so that cold air is unable to enter. Look to see if there is anything on the same circuit that could be causing electrical interference. For instance, a central heating pump on the same circuit may be creating problems. Clean the alarms thoroughly. Why aren’t my alarms interconnecting via RadioLink+ interconnect? Press and hold the ‘Test’ button for 10 seconds. Ensure that your alarms have been House-Coded. See that the earth cable hasn’t been wired into the ‘IC’ terminal. If the wires insulation has been tested with high voltage, replace the alarms and bases. Face the bases of the replacement alarms in the same direction, to maximise signal strength. Why aren’t my alarms interconnecting via hard-wired interconnect? Press and hold the ‘Test’ button for 10 seconds. Examine interconnecting wires to ensure they are wired properly. Check for short circuits. This is a circuit that is allowing current to pass along an unintended path. If the Live and Neutral wires have become entangled, the alarm will be impaired. See the wiring guide for advice on how to fix the wire and replace the alarm. How do I fix the test button, if it isn’t working? Press and hold the ‘Test’ button for 10 seconds. Establish that the alarm is connected to the base. Why aren’t alarm accessories working with all or some alarms? Ensure the alarms and their accessories are compatible. On a RadioLINK+ system, make sure they are House-Coded. If the hard-wired system is interconnected, make sure all the connections and wiring are correctly positioned for alarms and their accessories. See that the units are receiving power and all switches are turned on. Check if the alarms themselves are operational. https://www.youtube.com/watch?v=LHPrviAre_A Why is my Carbon Monoxide (CO) alarm sounding? Be very careful; there are likely to be dangerous levels of carbon monoxide present. Turn off the appliance and open all windows and doors. Then leave your home. Call the emergency number for the gas or fuel supplier. Do not re-enter the property until the alarm has stopped. Use an AudioLINK report to extract details about the incident (if applicable for the alarm). Note: Sparks sells Aico’s Ei3018 CO alarm, along with many other CO alarms. We’d suggest you read over the recommended sites for alarm placement. Why is my Carbon monoxide alarm giving a regular single beep? If the green light is off, examine the fuses and wiring. Use an AudioLINK report to extract details about the incident (if applicable for the alarm). Why is my CO alarm beeping irregularly? Examine the wiring and connections. If the green light has gone out, check the fuses. Check to see if there is any other appliance on the same circuit which could be creating electrical interference. Use an AudioLINK report to extract details about the incident (if applicable for the alarm). We hope this article has given you answers to any questions you may have regarding faults with Aico alarms. As you can gather from this guide, most problems are easy to address and solve in a few steps. Aico’s site has fantastic technical support if you find yourself in need of it.

Introducing Aico RadioLINK+ (wireless communication) and AudioLINK (data extraction)

With the advent of wireless technology, Aico saw a way to fundamentally change and improve the way home domestic heat alarms, fire alarms, smoke alarms, and CO alarms systems operate, especially via their RadioLINK+ and AudioLINK technologies. How Aico sees IoT as an opportunity to improve the fire alarm systems via wireless communication The Internet Of Things (IoT) radicalised the market, with devices transferring information over wireless networks with no need for human-to-computer interaction. Aico saw this as a golden opportunity to bring forth advanced wireless-interconnected fire protection systems. They are committed to the highest possible standards in terms of quality and responsiveness in their products, retaining the status as the market leader in fire and CO protection. Revolutionary RadioLINK and RadioLINK+ allows for easy wireless communication between alarms In the late 2000's Aico delved into the world of IoT, and this led to the interconnection of their fire alarm systems. They first began by connecting their heat and smoke alarms via radio frequency (RF), meaning that when one alarm in the system was alerted, they all sounded off. All this took was fitting a base or module directly onto the alarm, such as the RadioLINK base EI168RC, which complies with all alarms in the 140RC Series.  Once you have fitted all your bases and alarms you will need to connect them via ‘House-Coding’ upon install, to confirm they are communicating properly. If you already have an existing hard-wired system, RadioLINK alarms can be added in via what's called 'a hybrid system'. The advantages of a wirelessly connected network for alarms is obvious. RadioLINK integration uses a wireless connection that eliminates the need for burdensome wiring runs, salvages time at installation, reduces disruption time at installation, saves you money and makes it more straightforward to add new alarms and accessories. Next up would be RadioLINK+ -  a step up in alarm interconnection evolution. Setting up a RadioLink+ system requires control from a desktop appliance, which is demonstrated in the video below. Introduction to Aico RadioLink+ https://www.youtube.com/watch?v=7K-I0wqZff4&feature=youtu.be With the introduction of RadioLink+ and its module for connection, the slot for House Coding was shifted onto the actual alarm, allowing for far easier access without having to detach the alarm. The Aico Ei100MRF module connected a comprehensive number of newer Aico alarms - any number of the alarms - in the Ei160e Series system.  The Remote Alarm Interconnection meant only a single alarm in the RadioLINK+ system would need the Remote House Code inputting. From here, the RadioLINK+ just needed the new alarm or accessory to be added to allow for remote control, test and asset management. The RadioLINK+ data extraction system allows for entire system reports: this can help prevent instances of alarm tampering, and give you information about all your alarms activities. This information includes the RF signal strength between alarms, the age of alarms and CO levels (if there is a CO alarm in the system). AudioLink: extra convenience and analytical feedback straight to your mobile device Aico is serious about supplying the users of its alarms with up-to-date feedback, also offering AudioLINK functionality into many of its alarms, including all of their CO alarms. AudioLINK can be added as an App on your smartphone or tablet and will offer you a wide variety of useful functions including: Alarm activations Sensor status Record of testing Battery and backup cell status Carbon Monoxide (CO) levels recorded – in CO alarms only Background levels of CO – in CO alarms only Advice on dust contamination levels – Ei2110e only AudioLINK is available on all Aico CO alarms, including the Ei208 and Ei262, as well as other fire alarm types such as the Multi-Sensor Fire Alarm Ei2110e.  The remote nature of the data extraction technology granted by AudioLINK is that the extraction itself can be done without any need for removal of the alarm. This ensures the alarm will continue to detect even as you analyse your report. The report generated is easy to read and gives details of any incident immediately, meaning the feedback is instant. Data recorded by the AudioLINK technology can be extracted an infinite number of times and is also historic, meaning that all information is stored for life. Any information from the Alarm Status Report can be emailed directly from your device to multiple addresses, in the form of a PDF report. It is highly useful for easy integration with a housing management or maintenance system. For instance, Adactus Housing, who own and manage over 13,000 properties across England have fitted all their houses with Aico Ei208 due to the convenient and practical features that AudioLINK affords them. Ivan Meredith, Group Gas Compliance Manager at Adactus Housing, explained that: The added ability to provide us with historic data regarding the presence of CO is a fantastic benefit, helping us to take the right action when ensuring the safety of our tenants AudioLINK is also a godsend for Landlords, as it provides all the evidence necessary for the maintenance of a complete record that private Landlords need to retain by law. Aico's forward-thinking philosophy has resulted in a comprehensive fire alarm protection system that is completely wireless; RadioLINK+ and AudioLINK have both been embraced by housing management, landlords and members of the public alike.