  • Aico RadioLINK Panel Interface Module, interfacing RadioLINK alarms and other Fire Alarms

Aico RadioLINK Panel Interface Module, interfacing RadioLINK alarms and other Fire Alarms

Model No. Ei413 by: Aico
Availability: Usually 3-5 days

£42.03

Ex. VAT
List price £61.81
You save £19.78!
Free Delivery
(over £100+VAT, applies to zones A&B only , £6 +VAT otherwise)
Click & Collect
Order online & collect in store

The Aico Ei413 is a RadioLINK Panel Interface Module that provides an interface between RadioLINK alarms and accessories and Fire Alarm / Security Alarm Panels.

Please note: this item is non-returnable; due to the nature of this item, it has an electronic component and sensor, and we cannot take this item back for a refund as "unwanted".

The module will decode "Fire", "Carbon Monoxide (CO)", and "Fault" signals from RadioLINK devices and activate the relevant onboard relay contacts. The relays are wired to the input contacts on the Panel which will take appropriate action.

RadioLINK Panel Interface Module

  • Stand alone unit designed to interface to RadioLINK alarms, Fire alarm and security panels
  • Powered by 12-24V DC from panel or 3rd party source
  • Volt free output contacts
  • 5 Year Guarantee
  • RadioLINK Smoke Alarms & Accessories can be connected wirelessly to Security & Fire Panels
  • outputs (NC, C, NO) from Smoke Alarms sensing fire, Alarm fault (Low Battery or Contaminated Chamber), CO Alarm sensing CO
  • Panel can trigger all smoke / CO alarms to sound
  • Unique house coding feature
  • Blue LED to facilitate house coding and visual RF transmission indication
  • RF performance to EN300 220-1 in accordance with EN300 220-2
  • EMC performance to EN301 489-1 referencing EN301 489-3
  • Power Required: 12 V (range 11 to 30V)
  • Current Required: 15mA (Standby max.)
  • 60mA (Alarm max.)
  • RF Range*: Over 100 metres in free space
  • RF Frequency: 868.499 MHz
  • RF Multi-repeater Function: The module acts as an RF repeater to extend the range and reliability of the system.
  • li>Dimensions: 88mm X 88mm X 28mm
  • Weight: 125 grams
  • Outputs to Panel: Fire Relay - NC, NO, Contacts rating 30V, 1 amp (NO contact closes when an alarm / test message is received from a house coded smoke alarm or other device).
  • Fault Relay - NC, NO, Contacts rating 30V, 1 amp (NO contact closes when a low battery or fault message is received from a house coded smoke alarm or other device).
  • CO Relay - NC, NO, Contacts rating 30V, 1 amp (NO contact closes when an alarm / test message is received from a house coded CO alarm).
  • Note 1: after the fault condition has been cleared it will take up to 5 hours for the relay to reset. The fault condition is cleared by fixing the fault but it is also cleared by receiving an alarm / test message.
  • Inputs from Panel: Alarm:- Shorting the inputs of the SW terminals will put all the smoke / CO alarms into alarm.When this short circuit is removed it will send a “cancel alarm” message.
  • Alarm: - applying 11 - 30VDC to the ‘+’ and ‘- ‘ terminals will put all the smoke / CO alarms into alarm. When this voltage is removed it will send a “cancel alarm” message.
  • Temperature Range: 0ºC to 40ºC
  • Humidity Range: 15% to 95% Relative Humidity (non-condensing)
  • Operation:
    1. When the Ei413 receives a fire signal it will create a short circuit across the Detector Zone Input, resulting in a fire indication on the panel. A current limiting resistor may be required so check the panel manufacturers installation manual.
    2. When the Ei413 receives a fault signal it will open circuit the connection to the Detector Zone Input, resulting in a fault indication on the panel.
    3. A fire signal will override a fault signal