At Sparks, we distribute a wide range of fire protection systems, and in particular Fike Twinflex Pro is a reliable fire protection system you can count on.

Many say that a conventional 2-wire fire alarm system is often the natural choice for smaller applications or where budget constraints exist.

Continue reading this guide to find out about:

Fike’s TWINFLEXpro2 2-wire fire alarm system has long been known for its adaptability and cost-effectiveness within a variety of applications, big or small, making it one of the most flexible products on the market. 

Fike Twinflex Pro2: a Reliable Fire Protection System you can Count on

Why do we say this? This versatile fire alarm system from Fike incorporates the Twinflex Multipoint ASD using smoke and heat detection with an optional built-in sounder, allowing the whole system to be installed using only one pair of wires per zone.

That means easier, faster installations and cost savings. Building on those strengths and designed for ease of use and state-of-the-art monitoring, the LPCB-approved TwinflexPro2 is the next generation in 2-wire fire alarm reliability.

Fike Twinflex Pro2: Applications and Features

Fike Twinflex Pro2: Applications and Features

Some of the most popular applications for the versatile Fike Twinflex Pro2 conventional fire protection system are:

  • Schools
  • Nursing Homes
  • Bed and breakfast
  • Restaurants
  • Retail Stores
  • Museums
  • Office Buildings

Here are the features of the Fike Twinflex Pro2 system:

  • Allows detectors and sounders to be installed on the same pair of wires
  • Differentiates between call point or detector alarms
  • 4-line x 20-character LCD display
  • Checkpoint alarm verification feature
  • Available in 2, 4, and 8 zone panel versions
  • Highlighted selection menu
  • Event log storing up to 500 events
  • Up to 32 devices per zone
  • 3 enhanced test modes
  • Built-in EOL capability in all devices
  • Zone can be configured to day/night detection mode
  • Panel design changes to allow easier installation
  • 4 & 8 zone panels can now be configured to accept conventional devices on zones 5 to 8 with the optional conventional zone card
  • Protective cover to stop accidental damage when installing
  • Optional extended battery box with capacity for 2 x 12V 7.0Ah batteries

Fike Twinflex Pro2 - Panels and Accessories

Fike Twinflex Pro2 - Panels and Accessories

Here is the full list of Fike Twinflex Pro2 panels and accessories:

  • TwinflexPro² 2 Zone Control Panel (Fike 505-0002)
    Intelligent 2-wire control panel with 2 zones suitable for Twinflex devices. Dual-purpose flush and surface housing. Requires 2 x 12V 3.2Ah Sealed Lead Acid Batteries (not included).
  • TwinflexPro² 4 Zone Control Panel (Fike 505-0004)
    Intelligent 2-wire control panel with 4 zones suitable for Twinflex devices. Dual-purpose flush and surface housing. Requires 2 x 12V 3.2Ah Sealed Lead Acid Batteries (not included).
  • TwinflexPro² 8 Zone Control Panel (Fike 505-0008)
    Intelligent 2-wire control panel with 8 zones suitable for Twinflex devices. Dual-purpose flush and surface housing. Requires 2 x 12V 3.2Ah Sealed Lead Acid Batteries (not included).
  • TwinflexPro² Repeater Panel (Fike 505-0010)
    The repeater will only work with the 4 & 8 Zone Twinflex Pro2 panels using version 2.0 software onwards.
  • TwinflexPro2 Boxed Kit (Fike 604-0002)
    1 x TwinflexPro2 Zone Panel, 7 x Twinflex Multipoint ASD with sounder, 2 x Twinflex Manual Call Point c/w covers, 1 x Head Removal Tool.
  • TwinflexPro2 Boxed Kit (Fike 604-0004)
    1 x TwinflexPro2 4 Zone Panel, 7 x Twinflex Multipoint ASD with sounder, 2 x Twinflex Manual Call Point c/w covers, 1 x Head Removal Tool.
  • TwinflexPro2 Boxed Kit (Fike 604-0008)
    1 x TwinflexPro2 8 Zone Panel, 7 x Twinflex Multipoint ASD with sounder, 2 x Twinflex Manual Call Point c/w covers.
  • TwinflexPro² 4 Zone Expansion Card (Fike 505-0006)
    Can only be used with 505-0004 4 zone Twinflex Pro panel & Twinflex Pro 2
  • TwinflexPro² Conventional Expansion Card (Fike 505-0007)
    Can only be used with 4 zones & 8 Zone TwinflexPro2 panels.
  • TwinflexPro² Battery Conversion Kit (Fike 505-0020)
    Holds 2 x 7Ah batteries allowing for additional standby capacity of up to 72 hours.
  • TwinflexPro OSP (Fike 505-0040)
    PC programming software for all TwinflexPro panels; Requires a USB-A to USB-B interface lead (not supplied).

Buy TwinflexPRO by Fike

The Twinflex Multipoint ASD Detector - Features

The Twinflex Multipoint ASD Detector - Features

Using the Twinflex Multipoint ASD as part of the TWINFLEXpro² system means that when a detector is wired to the system, a sounder and strobe can also be connected without extra installation time or cost. This greatly reduces the number of points that need to be installed and the time it takes to install.

As the Twinflex Multipoint ASD offers 7 different modes of detection, the installation is made even simpler since one device suits all applications.

Whatever type of detection is required, it can be selected by the flick of a switch at the time of commissioning 3 different smoke modes, 2 fixed temperature heat modes, a rate of rise mode and a combination smoke or heat mode. 

The Twinflex Multipoint ASD is available with or without a full specification integral 90dBA sounder no extra devices need to be purchased when an audible warning is required. If extra sound is required or for areas that do not require detection, then a choice of several different standalone sounders or sounder beacons can be used on the same two wires

The Twinflex Multipoint ASD Detector - Detection Modes

The Twinflex Multipoint ASD Detector - Detection Modes

Two-wire installation - only one circuit per zone to connect detectors and sounders - installation savings can be as high as 40%. There are 7 modes of detection.

The Twinflex Multipoint ASD saves the cost of a sounder. Warning of head contamination, before going into false alarm. Easily removable for maintenance at height. 

The Twinflex Multipoint ASD Detector detection modes are:

  1. Smoke 1: Used where ionization detectors are normally fitted, especially when there are high ceilings or a risk of free-burning fires (chemical stores etc), or fires that need to be detected extremely quickly.
  2. Smoke 2: Used where optical detectors are normally fitted, when there is a risk of a smouldering fire and for escape routes.
  3. Smoke 3: Designed for use in areas that are prone to nuisance alarms. The reduced sensitivity linked with a time delay feature means that a higher concentration of smoke needs to be present for a constant time period before a fire decision is made.
  4. Heat 1: (Rate-of-Rise) – Used where a standard rate-of-rise detector would normally be used.
  5. Heat 2: (Standard Fixed Temperature – 58°C /136°F approximately) – A standard fixed temperature heat detector, suitable for domestic kitchens, etc.
  6. Heat 3: (High Fixed Temperature – 90°C / 194°F approximately) – High fixed temperature heat detector suitable for boiler rooms, commercial kitchens, etc.

Fike Twinflex Pro2 - Alarm Confirmation Feature

Fike Twinflex Pro2 - Alarm Confirmation Feature

Early warning fire alarm verification is often crucial. The disruption to business and costs associated with responding to false alarms can be enormous. The TwinflexPro2 offers alarm confirmation technology, which can help eliminate nuisance or false alarms.

Using the built-in alarm confirmation feature, until an alarm has been confirmed within an individual area, only that area is evacuated. At the same time, if an alarm is triggered in a common area, the device initiates a full alarm evacuating all surrounding areas. This unique panel feature is vital where two-stage alarms are required.

For example - when an alarm is indicated by an individual detector, the sounder for that device/zone is activated and the control panel carries out the configured number of confirmation checks on that specific zone.

If the alarm is confirmed, the control panel enters the fire state and all additional notification devices are activated throughout the facility. If the detector alarm is rejected, the sounders on the zone are silenced, and the detector in alarm is reset.

For safety, activating a call point will override any delays or confirmation settings.

Twinflex Pro2 Detectors and Accessories

Twinflex Pro2 Detectors and Accessories

Here are the Twinflex Pro2 Detectors and Accessories - many of which can be found on our website for purchase.

  • Twinflex Multipoint ASD Detector (Fike 204-0003)
    A multifunction smoke and heat detector with three smoke detection modes, three heat detection modes and one combination mode. Built in ‘End of Line’. These options are set by the DIL switch. Supplied complete with mounting base and dust cover.
  • Twinflex Multipoint ASD Detector with Sounder (Fike 204-0001)
    As above but complete with an inbuilt sounder featuring three sound patterns and two volume levels.
  • Twinflex Multipoint ASD Detector with Sounder/Strobe (Fike 204-0012)
    As above but complete with an inbuilt sounder/strobe featuring three sound patterns and two volume levels and an LED strobe array. Visual indicator strobe.
  • Twinflex Manual Call Point (Fike 406-0006)
    Manual call point with resettable element reset key, back box, adaptor plate for flush mount and inbuilt ‘End of Line’ set by DIL switch (includes call point cover).
  • Twinflex Manual Call Point Weatherproof (Fike 406-0007)
    IP65 weatherproof manual call point with resettable element, reset key, back box and inbuilt ‘End of Line’ set by DIL switch (includes call point cover).
  • Twinflex Hatari Sounder: Red/White (Fike 302-0001 + 302-0002)
    Sounder with 97dB adjustable output and inbuilt ‘End of Line’ set by DIL switch. Supplied complete with mounting base.
  • Twinflex Sound Point: Red/White (Fike 313-0021 + 313-0022)
    Sounder with 85dB output, three sound patterns and inbuilt ‘End of Line’ set by DIL switch. Supplied complete with back box and flush adaptor plate.
  • Twinflex Hi Point (Fike 302-0004)
    IP55 Internal / External horn sounder with 90dB output, three sound patterns and inbuilt ‘End of Line’ set by DIL switch. Supplied complete with back box and flush adaptor plate. Suitable for indoor and outdoor applications.
  • Twinflex Flash Point (Fike 302-0012)
    Low profile sounder and LED visual indication beacon with 90dB output, three sound patterns and inbuilt ‘End of Line’ set by DIL switch. Supplied complete with mounting base. 
  • Twinflex Flash Point: Domed (Fike 302-0022)
    Sounder and LED visual indication beacon with 90dB output, three sound patterns and inbuilt ‘End of Line’ set by DIL switch. Supplied complete with mounting base.
  • Twinflex Flash Point: Weatherproof (Fike 302-0023)
    IP52 LED visual indication beacon with inbuilt ‘End of Line’ set by DIL switch. Supplied complete with mounting base (note, this item does not include a sounder, i.e. beacon only).
  • Twinflex Input / Output Module (Fike 802-0006)
    Relay interfacing module including two sets of 2A-rated SPCO relay contacts, one monitored input and inbuilt ‘End of Line’.
  • ASD Head Removal Tool (Fike 25-0046-201)
    To remove the optical chamber of Multipoint ASD detectors. The tool may be mounted onto a pole for high-level access. This tool fits directly onto the solo poles range of detector test equipment.

Buy Twinflex Multipoint Detectors

Many of the sounders and panels in the Fike Twinflex Pro2 range are available at Sparks via, Conventional Fire Alarms. For any further information, do not hesitate to contact us. The above is inspired by a guide from Fike on their Fike Twinflex Pro2. The Fike Twinflex Pro2 is a Reliable Fire Protection System you can Count on.