Automatic Key Operated Emergency Lighting Test Switch to 10 min, 1h, and 3h

Model No. ELT10 by: CP Electronics.
£63.30 Ex. VAT
This item requires:

Free delivery
(over £100 +VAT, applies to zone A and B only, £6 +VAT otherwise)

Usually 3-5 days

Click & Collect

Order online & collect in store

Our customers love us - read their reviews

Wishlist Ask a question Compare

A simple method to test the functioning of emergency lighting: this key switch is designed to interrupt the supply to emergency luminaires for a set amount of time (10 minutes, 1 hour, or 3 hours). There is no risk of depleting the batteries during this test period.

The emergency lighting test switches provide a cost effective solution to the testing of emergency luminaires. It is a requirement that all emergency luminaires are tested regularly so that an adequate level of illumination is given by the lamps under emergency conditions. This can be achieved by interrupting the supply to the luminaires at the distribution board. Self test fittings are available but these can be costly. Alternatively our Emergency Lighting Test Switch can be used to simplify testing by providing local automatic switching. This particular switch - the ELT10 - is suitable for offices, schools, colleges, industrial and retail.

Testing

The ELT10 emergency lighting test switch is designed to test the function of emergency luminaires. A key switch is used to interrupt the supply to the luminaires for a pre-programmed period of time. At the end of the time period the supply to the luminaires is automatically re-instated. The result is that there is no risk of depleting the batteries in the emergency fitting. 

Three pre-programmed test intervals are available:

  • 10 minutes.
  • 1 hour.
  • 3 hours.

The unit will power up with the SUPPLY ON lamp illuminated—the supply will be connected to the output. Turn and release the key switch to select the 10 minute test interval. Turn and release again to select the next test interval—the supply will be disconnected from the output for the duration of the test. To cancel a test, turn and release the keyswitch until the SUPPLY ON lamp illuminates.

Product Specifications

  • Load
    • 10 Amp incandescent lighting.
    • 6 Amp fluorescent lighting.
    • 3 Amp compact fluorescent lighting.
    • 3 Amp low energy lighting.
    • 3 Amp low voltage lighting (switch primary of transformer).
    • Fluorescent lighting (max 6 fittings recommended).
    • For fluorescent lighting total power factor correction capacitance must not
      exceed 40 F.
  • Supply Voltage: 220-240 Volts AC 50 Hz.
  • Timing Period: 10 minutes, 1 hour, 3 hours.
  • Fixing Method: Surface fixing 25mm deep plastic surface mount moulded box.
  • Flush fixing 25mm steel wall box or 32mm deep cavity wall box.
  • Terminal capacity: 2.5mm2
  • Material: Flame retardant ABS TYPE Class 2
  • Temperature: -10°C to 35°C
  • Conformity: EMC-89/336/EEC, LVD-73/23/EEC
Switches & Sockets Specific
Brand Danlers
Finish White
Gang 1
Insert Black
Plate Plastic
Style White Moulded
Type Switch

 

Follow us for exclusive offers and tips about lighting, switches and sockets

Get in touch

Telephone 020 7263 8007

Fax 020 7272 3007

Sparks Electrical Wholesalers Ltd, 659-661 Holloway Road, Archway, London, N19 5SE, United Kingdom
Registered in England. Company No. 2238028. VAT Reg No: GB 505 6899 17. Copyright © 2003-2020 SparksDirect

Award Winning Ecommerce from Cyber-Duck