Fike 204-0012 Twinflex Multipoint ASD Detector with Sounder and Strobe, Heat and Smoke

Model No. 2040012 by: Fike.
This item requires:

Free delivery
(over £100 +VAT, applies to zone A and B only, £6 +VAT otherwise)

2 - 3 Days Delivery

Click & Collect

Order online & collect in store

Our customers love us - read their reviews

Wishlist Ask a question Compare

This is the Fike 204-0012 Twinflex ASD Multipoint detector complete with sounder and strobe, which can be used as a smoke, heat, or multisensor detector. It comes complete with the base plate. Multifunction smoke and heat detector with seven detection modes, ideal for the Fike Twinflex Pro range of 2-wire fire alarm control panels.

The Twinflex Multipoint ASD is a plug-in type smoke detector that utilises a photo-electric sensing chamber to make a measurement corresponding to smoke density. The device also incorporates a thermistor sensing circuit to allow for accurate heat measurement. These elements allow the device to be configured to a smoke, heat or combined setting. This device is only compatible with the Twinflex control panels (and their associated detection and alarm equipment) and also incorporates a sounder beacon.

7 modes of detection: 3 x smoke detection modes, 3 x heat detection modes, and 1 x combination mode. You can select your required option using the in-built DIL switches located within the detector.

Fike 204-0003 Twinflex Multipoint ASD Detector - Features

  • Part of the Twinflex Pro intelligent 2-wire fire alarm system.
  • Complete with a built-in sounder and a mounting plate.
  • Self-calibrates every 6h.
  • Continuously monitors for dust contamination. 
  • Can be used as a smoke detector, a heat detector, or a multi-sensor.

Fike 204-0003 Multipoint Detector - Technical Data

  • Dimensions: 107mm diameter x 75mm
  • Operating temperature: -10 deg C to +50 deg C
  • Operating Voltage Range: 18V to 32V DC
  • Operating Current Quiescent: 109 uA (Typical)
  • End of line ON if applicable: +50 uA (Typical)
  • Alarm Sounding – Sounder High: 10.54 mA (Typical)
  • Alarm Sounding – Sounder Low: 4.92 mA (Typical)
  • Alarm Sounding – Sounder Off: 2.58 mA (Typical)
  • Alarm Activated: 17.92 mA (Typical) (in addition to Alarm Sounding)
  • LED Operation Detector in Normal State (Smoke): Flash at 20 second intervals
  • Detector in Normal State (Heat): Double flash at 20 second intervals
  • Detector at EOL: Flash at 5 second intervals
  • Detector in Fault: Flash at 1.3 second intervals
  • Detector Detecting Fire: Flash at 0.7 second intervals
  • Detector in Fire (once processed at panel): Continuous
  • Sounder High: 2.0 SLU (V3 panel), 10.5 DLU (Pro panel)
  • Sounder Low: 1.0 SLU(V3 panel), 5.0 DLU (Pro panel)
  • No Sounder: 0.5 SLU(V3 panel), 3.0 DLU (Pro panel)
  • Volume Level (@ 1m anechoic, Dual Tone): Sounder High: 90+ dB(A), Sounder Low: 70+ dB(A)
  • Flammability: UL94-V2
  • IP Rating: IP 21 rated

Note: picture is for information purposes only.


Follow us for exclusive offers and tips about lighting, switches and sockets

Get in touch

Telephone 020 7263 8007

Fax 020 7272 3007

Sparks Electrical Wholesalers Ltd, 659-661 Holloway Road, Archway, London, N19 5SE, United Kingdom
Registered in England. Company No. 2238028. VAT Reg No: GB 505 6899 17. Copyright © 2003-2016 SparksDirect

Award Winning Ecommerce from Cyber-Duck