Fluke 1663 Multifunction Installation Tester for Hard-working Professionals

Model No. 1663 by: Fluke
Availability: 6 - 8 Weeks Delivery
£1,280.00

£799.00

Ex. VAT

Free delivery

(over £100+VAT, applies to zones A and B only, £6+VAT otherwise)

This instrument is ideal for professional users–full-featured functionality, advanced measurement capability, yet it is still easy to use. Operation is intuitive and easily mastered by all levels of field workers.

Fluke 1663 Multifunction Installation Tester - Features

  • Full featured tester for installation professionals
  • Tests to all local regulations and provides test results for complete documentation
  • It replaces the existing Fluke 1653.
  • Tests continuity at L-N, N-PE inputs
  • Tests smooth dc sensitive RCDs (Type B)
  • Tests earth resistance, voltage, and frequency
  • Offers multiple test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V
  • Checks wiring polarity to detect broken N wires
  • Measures insulation resistance and loop and line resistance
  • Includes Z-max memory for loop tests to support easy evaluation of the highest loop test value
  • Provides unique zero adapter for fast, reliable and accurate test lead and mains cord compensation
  • Measures motor windings with continuity test
  • Calculates prospective earth fault current (PEFC/IK) and prospective short-circuit current (PSC/IK)
  • Measures RCD switching time and tripping level (ramp test)
  • Measures trip time and current for RCD type A & AC in one test
  • Measures RCD variable current
  • Provides automatic RCD test sequence
  • Includes a phase sequence indicator
  • Safety rated CAT III 500V, CAT IV 300V
  • Comes with hard carrying case, padded carrying and waist strap, and remote control probe and lead

The Fluke 1663 Multifunction Installation Tester Includes:

  • 6x AA (IEC LR6) cell batteries
  • C1600 hard carrying case
  • Zero adapter
  • Heavy duty mains cord
  • STD standard test lead set
  • Padded carrying and waist strap
  • Quick reference guide
  • TP165X remote control probe and lead
  • User's manual on CD-ROM

Fluke 1663 Multifunction Tester - Specs

  • AC voltage measurement
  • Range: 500 V
  • Resolution: 0.1 V
  • Accuracy 45 Hz – 66 Hz: 0.8% + 3
  • Input impedance: 360 kO
  • Overload protection: 660 V rms

Continuity testing (RLO)

  • Range (autoranging): 20 O / 200 O / 2000 O
  • Resolution: 0.01 O / 0.1 O / 1 O
  • Open Circuit Voltage: >4 V

Insulation resistance measurement (RISO)

  • Test voltages: 50-100-250-500-1000 V
  • Accuracy of Test voltage (at rated test current): +10%, -0%
  • Test voltage: 50 V, 100 V, 250 V, 500 V, 1000 V
  • Insulation resistance range: 20 MO /50 MO, 20 MO / 100 MO, 20 MO / 200 MO, 20 MO / 200 MO / 500 MO, 20 MO / 200 MO / 1000 MO
  • Resolution: 0.01 MO / 0.1 MO, 0.01 MO / 0.1 MO, 0.01 MO / 0.1 MO, 0.01 MO / 0.1 MO / 1 MO, 0.01 MO / 0.1 MO / 1 MO
  • Test current: 1 mA @ 50 kO, 1 mA @ 100 kO, 1 mA @ 250 kO, 1 mA @ 500 kO, 1 mA @ 1 MO

Loop and line impedance (ZI)

  • Range: 10 O / 0.001 O / High current mO mode
  • Resolution: 0.01 O / 0.1 O / 1 O

Prospective earth fault current, PSC test

  • Range: 1000 A / 10 kA (50 kA)
  • Resolution: 1 A / 0.1 kA
  • Computation: Prospective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.

RCD testing, RCD types tested

  • RCD Type: AC¹, G²,S³
  • Model 1663: A4, AC¹, G²,S³
  • Notes: ¹Responds to AC; ²General, no delay; ³Time delay; 4Responds to pulsed signal; 5Responds to smooth DC signal

Tripping speed test (?T)

  • Current settings¹: 10-30-100-300-500-1000 mA – VAR, 10-30-100 mA
  • Multiplier: x ½, x 1, x 5
  • Measurement range: RCD Type G: 310 ms, 50 ms; RCD Type S: 510 ms, 160 ms
  • Notes: ¹1000 mA type AC only; 700 mA maximum type A in VAR mode; VAR mode not available for type B.

RCD/FI-Tripping Current Measurement/Ramp Test (I?N)

  • Current range: 30% to 110% of RCD rated current¹
  • Step size: 10% of I?N²
  • Dwell time: Type G 300 ms/step, Type S 500 ms/step
  • Measurement accuracy: ±5%
  • Specified trip current ranges (EN 61008-1): 50% to 100% for Type AC, 35% to 140% for Type A (>10 mA), 35% to 200% for Type A (=10 mA), 50% to 200% for Type B, ²5% for Type B
  • Notes: ¹30% to 150% for Type A I?N > 10 mA, 30% to 210% for Type A I?N = 10 mA, 20% to 210% for Type B

Earth Resistance Test (RE)

  • Range: 200 O / 2000 O
  • Resolution: 0.1 O / 1O
  • Frequency: 128 Hz
  • Output Voltage: 25 V

 

  • Phase Sequence Indication Icon: icon phase sequence indicator, Phase Sequence indicator is active.
  • Size (L x W x H): 100mm x 250mm x 125mm
  • Weight (incl. batteries): 1.3 Kg
  • Battery size, quantity: Type AA, 6 ea.
  • Sealing: IP-40
  • Safety: Complies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA –s82.02.01 2000 and CAN/CSA c22.2 No. 1010 2nd edition
  • Overvoltage: CAT III / 500V; CAT IV 300V
  • Performance: EN61557-1 to EN61557-7 Second Edition and EN61557-10 Second Edition

Need more detailed specs?

Ask a question

Note: HTML is not translated!

Shipping

Sparks Direct delivers via courier to the UK only; the standard delivery charge is £6 + VAT for all orders under £100 + VAT. If your order is over £120, you get free delivery (unless there's a special delivery charge for the items you wish to order or you're in shipping zone C or D). Full details for shipping charges can be found via Terms and Conditions.

If the items you order are in stock and the order is placed before 1.00pm, delivery can be made within 1-2 working days. If the items are not in stock, we will inform you via email how long it will take or ask for your confirmation if there's a long lead time.

Returns

We offer 30-day returns for unwanted items - please email us to request a returns number which will need to be quoted when the items are returned. For faulty items or items damaged in transit, please advise via email, and an appropriate returns number will be provided. Full details concerning returns and refunds can be found via our Terms and Conditions.