Sale Icon
Review Icon
Free Delivery Icon
Hager JK224BG 24 way 250A TPN Distribution Board Type B Glazed Door Invicta 3 (17th edition)

Hager JK224BG 24 way 250A TPN Distribution Board Type B Glazed Door Invicta 3 (17th edition)

This is a Hager TP&N Distribution Board Type B, 24 way distribution board (250A), with a glazed ..

Model: JK224BG

£613.85 Ex. VAT

Hager VML008 8 Way Metal Enclosure (empty) with DIN Rail, Surface Mounting IP2XC max. 100A Pure White, Hager Fuseboard Design 10 VML008

Hager VML008 8 Way Metal Enclosure (empty) with DIN Rail, Surface Mounting IP2XC max. 100A Pure White, Hager Fuseboard Design 10 VML008

This is the Hager Design 10 VML008 - a Hager 8 Way Metal Enclosure (empty) with DIN Rail, Surface Mo..

Model: VML008

£50.34 Ex. VAT

Hager VW110G IP55 10 Way Insulated Consumer Unit with 100A Switch Incomer and Glazed Door, Hager Fuseboard

Hager VW110G IP55 10 Way Insulated Consumer Unit with 100A Switch Incomer and Glazed Door, Hager Fuseboard

This is the Hager VW110G 10 way 100A Switch incomer insulated IP55 rated consumer unit with glazed d..

Model: VW110G

£122.78 Ex. VAT

Hager VMLF110 10 Way Consumer Unit Flush 100A Switch Disconnector Incomer, Hager Fuseboard D10 VMLF110

Hager VMLF110 10 Way Consumer Unit Flush 100A Switch Disconnector Incomer, Hager Fuseboard D10 VMLF110

This is the Hager VMLF110 - a Hager Design 10 consumer unit, all metal, for flush mounting, ideal fo..

Model: VMLF110

£78.91 Ex. VAT

Hager VMLF910C 10 Way Flush Consumer Unit Dual RCD 100A DP Isolator + 2 x 100A 30mA Type A RCDs Metal Clad Hager Fuseboard

Hager VMLF910C 10 Way Flush Consumer Unit Dual RCD 100A DP Isolator + 2 x 100A 30mA Type A RCDs Metal Clad Hager Fuseboard

This is the Hager VMLF910C, a 10 way consumer unit dual RCD - Flush metal clad consumer unit supplie..

Model: VMLF910C

£144.93 Ex. VAT

Hager VMLF916C 16 Way HI Flush Consumer Unit Split Load 100A DP Isolator + 2 x 100A 30mA Type A RCDs Metal Clad Hager Fuseboard

Hager VMLF916C 16 Way HI Flush Consumer Unit Split Load 100A DP Isolator + 2 x 100A 30mA Type A RCDs Metal Clad Hager Fuseboard

This is the Hager VMLF916C, a 16 way High Integrity consumer unit dual RCD - Flush metal clad consum..

Model: VMLF916C

£157.64 Ex. VAT

Hager JK1/JK2 Door Lock Kit with One Key, Hager JK222PK Quarter turn lock and Key for Consumer Units

Hager JK1/JK2 Door Lock Kit with One Key, Hager JK222PK Quarter turn lock and Key for Consumer Units

This is the Hager JK1/JK2 Door Lock Kit with One Key - it is a Hager JK222PK Quarter turn lock and K..

Model: JK22A

£15.04 Ex. VAT

Hager JK11254S 125A 4 Pole JK1 Switch Incomer Kit for Invicta 3 Distribution Boards, Incomer Isolator Kit

Hager JK11254S 125A 4 Pole JK1 Switch Incomer Kit for Invicta 3 Distribution Boards, Incomer Isolator Kit

This is the Hager JK11254S 125A 4 Pole JK1 Switch Incomer Kit. It is a 4 Pole 125A three phase incom..

Model: JK11254S

£85.06 Ex. VAT

Hager VML110RK 10 Way 100A Main Switch Incomer Consumer Unit Round Knockouts (Design 10)

Hager VML110RK 10 Way 100A Main Switch Incomer Consumer Unit Round Knockouts (Design 10)

Introducing the Hager Design 10 VML110RK 10 Way 100A Isolator Incomer Metal Clad Consumer Unit for S..

Model: VML110

£44.00 Ex. VAT

Hager VML90810CU 8 + 10 Way High Integrity Dual Row Configurable Consumer Unit 100A Main Switch 2 x 100A 30mA Type A RCCB Hager Fuseboard

Hager VML90810CU 8 + 10 Way High Integrity Dual Row Configurable Consumer Unit 100A Main Switch 2 x 100A 30mA Type A RCCB Hager Fuseboard

This is the Hager VML90810CU, a 8 + 10 Way Dual Row 100A Main Switch 2 x 100A RCCB type A 30mA, a Hi..

Model: VML90810

£192.95 Ex. VAT

Hager VML91820CU Dual Row HI Configurable 18 + 20 Way Consumer Unit 100A Switch Disconnector 2x100A 30mA Type A RCCB Hager Fuseboard Amendment 3

Hager VML91820CU Dual Row HI Configurable 18 + 20 Way Consumer Unit 100A Switch Disconnector 2x100A 30mA Type A RCCB Hager Fuseboard Amendment 3

This is the Hager Design 10 VML91820CU high integrity metal consumer unit, Hager dual row configurab..

Model: VML91820

£203.97 Ex. VAT

Hager VMLF114 Flush 14 Way Consumer Unit 100A Mains Switch Disconnector Incomer Design10 Amendment 3

Hager VMLF114 Flush 14 Way Consumer Unit 100A Mains Switch Disconnector Incomer Design10 Amendment 3

This is the Hager VMLF114, a Flush 14 Way Consumer Unit 100A Mains Switch Disconnector Incomer - par..

Model: VMLF114

£84.58 Ex. VAT

Hager JK11003S 100A 3 Pole Mains Switch Incomer Kit, Three Pole Switch Disconnector / JK1 Isolator Kit

Hager JK11003S 100A 3 Pole Mains Switch Incomer Kit, Three Pole Switch Disconnector / JK1 Isolator Kit

This is the Hager JK11003S 100A 3 Pole JK1 Switch Incomer Kit. It is a Hager Invicta 3 Incomer Isola..

Model: JK11003S

£37.47 Ex. VAT

Hager JK11004S 100A 4 Pole Mains Switch Incomer Kit, Four Pole Switch Disconnector / JK1 Isolator Kit

Hager JK11004S 100A 4 Pole Mains Switch Incomer Kit, Four Pole Switch Disconnector / JK1 Isolator Kit

This is the Hager JK11004S 100A 4 Pole JK1 Switch Incomer Kit. It is a Hager Invicta 3 Incomer Isola..

Model: JK11004S

£53.64 Ex. VAT

Hager JK11253S 3 Pole 125A Switch Disconnector, Mains Isolator for Hager Distribution Boards

Hager JK11253S 3 Pole 125A Switch Disconnector, Mains Isolator for Hager Distribution Boards

To be used with the Hager Distribution Boards, Hager TPN DB Note: picture is informative..

Model: JK11253S

£62.55 Ex. VAT

Hager VML91214 12 + 14 Dual Row HI Configurable Consumer Unit 100A Switch 2 x 100A 30mA Type A RCCB VML91214CU Hager Fuseboard 18th Edition

Hager VML91214 12 + 14 Dual Row HI Configurable Consumer Unit 100A Switch 2 x 100A 30mA Type A RCCB VML91214CU Hager Fuseboard 18th Edition

This is the Hager VML91214CU, a 12 + 14 Dual Row 100A Switch Disconnector Isolator Dual Row 2 x 100A..

Model: VML91214

£198.70 Ex. VAT

Showing 33 to 48 of 212 (14 Pages)

Related Articles

What is an AFDD and Who Needs an Arc Fault Detection Device?

We have recently lowered the prices for the Hager AFDDs and we thought we should introduce the Arc Fault Detection Devices - what they are, who needs them, and what are their use. Keep reading to find out more about:Why Arc Fault Detection Devices and Where are AFDDs used?What is an AFDD? What does an AFDD Do?How do AFDDs work?Are AFDDs Required and Who Needs an Arc Fault Detection Device?AFDDs at Sparks - Hager AFDDs at a Discounted PriceHager ProTools for Hager AFDDs - FeaturesHow to Test a Hager AFDDArticles on AFDDs - Further readingWhy Arc Fault Detection Devices and Where are AFDDs used?After the publication of Amendment 2 of the 18th Edition Wiring Regulation on the 28th of March 2022, the use of AFDDs (Arc Fault Detection Device) has been made mandatory use in certain types of installations.  Regulation 421.1.7 now states AFDD conforming to BS EN 62606 shall be provided for single-phase AC final circuits supplying socket-outlets with a rated current not exceeding 32 A in:Higher Risk Residential Buildings (HRRB)Houses in Multiple Occupation (HMO)Purpose-Built Student Accommodation (PBSA)Care homesFor all other premises, the use of AFDDs is recommended for single-phase AC final circuits supplying socket outlets not exceeding 32 A. In the notes of the 18th Edition, there is guidance on the language used in BS 7671. There is also a table describing verbal forms which may be used and the verbal form for recommendation can be translated to “should”.Buy Hager AFDDs at SparksWhat is an AFDD? What does an AFDD Do?An AFDD (Arc Fault Detection Device) is designed to detect the presence of dangerous electrical arcs and disconnect the circuit affected, in order to protect human life and the electrical wiring circuit. An arc fault is where an electrical current jumps between two conductive materials. There can be a parallel arc fault or a series arc faults. One of the most common causes of arcs are worn contacts in the electrical equipment, loose connections, or break in the cables. Arc faults can occur for a number of reasons such as breaks in a cable, damaged cables as a result of DIY projects, defective plugs, rodent bites, cable wear, incorrect bonding, etc. What an Arc Fault Detection Device do is use microprocessor technology to analyse the waveform of the electricity, detect any unusual or higher current jump, and terminate the power to the affected circuit to prevent a fire. There are the MCBs and RCBOs that do the same function, but the AFDDs are more sensitive to arcs than these conventional circuit protection devices. The purpose of an AFDD is to make sure no electrical fire takes place; whether there's a short-circuit or an overload, an earth leakage current or an overvoltage, or a dangerous electric arc, an AFDD detects and trips the circuit. How do AFDDs work?Unlike a circuit breaker which detects overloads and short circuit currents and RCDs which detect current imbalance, an AFDD utilises electronic technology to analyse the signature (waveform) of an arc to differentiate between normal arcing and arcing faults. Although AFDD manufacturers may employ different technologies to analyse arcs, the end result is the same, detecting parallel arcs (line to line, line to neutral and line to earth) and series arcs (arcing within one of the conductors). Upon detection of an arcing fault, the AFDD disconnects the final circuit from the supply. AFDD manufacturers test for numerous possible operating conditions and design their devices to constantly monitor for arcing faults.AFDDs are designed and tested to not respond to arcing under normal operation of equipment such as vacuum cleaners, drills, dimmers, switch mode power supplies, fluorescent lamps, etc. In addition, they are designed and tested to continue to respond to arc faults whilst the aforementioned equipment is being operated.Are AFDDs Required and Who Needs an Arc Fault Detection Device?Though much more expensive than a regular RCBO or MCB, an AFDD can be a lifesaver especially where there is more than one life on the line. So far Amendment 2 only recommends the use of AFDD in domestic use, but they require Arc Fault Detection Devices to be used in certain applications. UK fire statistics identify that electrical fires are still unacceptably high. The use of overcurrent and residual current protection has vastly reduced the risk and consequence of electrical fires. Electrical fires can be a silent killer occurring in areas of the home that are hidden from view and early detection. If used, an AFDD should be placed at the origin of the circuit to be protected. Examples of locations where AFDDs should be used are:premises with sleeping accommodationlocations with a risk of fire due to the nature of processed or stored materials, i.e. BE2 locations (e.g. barns, woodworking shops, stores of combustible materials)locations with combustible constructional materials, i.e. CA2 locations (e.g. wooden buildings)fire propagating structures, i.e. CB2 locationslocations with endangering of irreplaceable goods.AFDDs at Sparks - Hager AFDDs at a Discounted PriceAt Sparks, we are proud to stock and distribute the Hager AFDDs with AFDD ProTools diagnostic software for the best price - even a discounted price at the moment. The next generation of single module wide AFDDs comes with advanced ProTools diagnostic software as standard. Exclusive to Hager AFDDs, ProTools provides the professional installer with advanced fault-finding and rectification capabilities.Best price for Hager Arc Fault Detection DeviceHager ProTools for Hager AFDDs - FeaturesProTools - On-Board Diagnostics: With the ability to identify 8 statuses, the on-board diagnostics within the device save time and effort in fault finding.ProTools - Diagnostic Support: Access additional diagnostic support and guidance when on-site via the Hager Pilot app on your mobile device.ProTools - In Situ Software Upgrades: The ability to update software via Bluetooth connectivity as and when new electrical signatures are detected, eliminates the need to remove or replace the device in the futureRCBO & MCB Configurations: Available in both RCBO and MCB single module configurations.Backwards Compatibility: Save time on site and upgrade existing Hager MCB-based installations to AFDD with minimal cost and disruption to you and your customers.Hager Technical Support: Receive technical advice with device installation and fault finding from the Hager Telford-based team of technical experts that are on hand to support you. The Hager AFDD with ProTools guarantees that you’re getting that fit-and-forget assurance you’ve come to expect from their products. In addition to the On-Board Diagnostics, the Hager Pilot app contains diagnostic guides providing a step-by-step approach to fault finding, ensuring that the professional electrician can quickly and easily identify the cause of any problems encountered. Exclusive to Hager ProTools, all the AFDDs come equipped with Bluetooth functionality to enable in situ software upgrades.How to Test a Hager AFDDYou don’t need to specifically test the AFDD element as they have a self-test feature. As per the requirements of the product standards, the AFDD must perform a daily self-test. The Hager AFDD undertakes a self-test every hour and should a fault be identified, it will switch off the circuit and the LED status indicator will show that the self-test has failed. AFDDs have a test button on them which doubles up as the RCD test button if it is an RCBO/AFDD. In line with long-standing regulations, this is required to be pressed once every 6 months when the device should trip and will simply be switched back on by the user.Purchase Hager AFDD todayArticles on AFDDs - Further readingThis article was inspired from and partially taken from some of the most popular and informative articles and guides on the AFDDs, including:Single Mod Arc Fault Detection Device via Hager. Beama guide to arc fault detection devices AFDDs here. What you need to know about arc fault detection devices - AFDDs, via, Electrician Courses for you. Arc Fault Detection Devices (AFDD) via The IET. Hager Launches New AFDD Solution, the press release. Arc Fault Detection - via, Electrium. AFDDs: how and when to use them, via, ECA today. 

The 18th Edition Wiring Regs: there's still so much to Know and Understand!

The 18th Edition Wiring Regulations brought about a whole range of new rules to the electrical industry. The regulations set out a number of significant changes and guidance on protection against overvoltage. They also instructed on EV charging point installation and guaranteed the energy-efficiency of electrical installations. The rules went into effect on January 2019. As well as the significant nature of rule changes, there was an added element of complexity. In a survey conducted by Hager, a large portion of professional electricians admitted to not understanding all the changes. This, of course, poses a problem as registered electricians are the ones who are supposed to be the most knowledgeable in this subject area. If they find the 18th Edition difficult then it must be complicated! In this article, Sparks will endeavour to explain key parts of the 18th Edition Wiring Regs in layman's terms and help everyone understand the regulations more clearly. The sections of the 18th Edition that have caused the most confusion Hager’s research indicated that an incredible 45 percent of those in the electrical trade did not completely understand all the rule changes of the 18th Edition. An entire third of those surveyed said they would not be prepared to comply with the 18th Edition’s amendments. Two topics kept coming up in regards to complex changes: Arc Fault Detection Devices (AFDDs) and surge protection laws. Nearly half of respondents pointed to AFDDs as an issue they were unclear on, whilst almost a third cited surge protection as their main concern. An AFDD is designed to detect the presence of dangerous electrical arcs (prolonged discharges) and disconnect the circuit affected. Meanwhile, a surge is a transient overvoltage that lasts for a short duration and increases in voltage measured between two or more conductors. Surge Protection Devices (SPDs) protect electrical equipment from these transient overvoltages.Buy Hager AFDDs at Sparks What the 18th Edition has to say on SPDs and AFFDs Section 443 is very clear in outlining the importance of protection against overvoltages, and the entire section has been re-written in the 18th Edition. These changes include surge protection rules for all kinds of dwellings, except where the value of the property does not warrant the protection. This section states that overvoltage protection: shall be provided where the result of an overvoltage would affect different aspects; such as danger to life, public services, commercial or industrial activity and more The requirements also stipulate they are needed where there is a large number of co-located individuals, for instance, in social housing. This has greatly increased the need to install SPDs in all manners of facilities. Sparks sells all manners of SPDs that are compliant with the 18th Edition.Classification of SPDs and AFFDs - important details contractors must get right Confusion may arise from the different ‘types’ of SPDs which are available - for instance, the Hager 14 described above is classified as Type 2. Type 2 SPDs are used in primary distribution boards when there is no need for a Type 1 SPD. Type 1 SPDs can discharge only partial lighting current and, like the Type 2, are used mainly on primary distribution boards. However, unlike the Type 2, these SPDs do not offer an adequate amount of protection level to prevent overvoltage. They must be used in conjunction with Type 2 SPDs. Type 3 SPDs, however, have a relatively low discharge capacity. This means they are not used on primary distribution keyboards and only in a supplementary way - for ‘sensitive loads’. It is essential that contractors understand the different classifications of SPDs. Primary distribution keyboards provide and regulate power throughout your home through a multi-core run cable.Buy AFDDs by Hager via Sparks The 18th Edition six months later - has the industry got to grips with it? Reaction to the changes made by the 18th Edition have been largely positive. Michael Kenyon, the technical engineer at Bureau Veritas, said: The introduction of the 18th Edition regulations has ushered in a new era of best practice for surge protection, EV charging point installation and energy efficiency. Michael goes on to say that these new rules on surge protection are making a huge impact in public sector buildings such as hospitals. Demand for charging points is massively on the rise, so it is essential that contractors have an understanding of how to test them. The initial benefit is the added peace of mind this knowledge of surge protection grants to hospitals. However, there are other benefits that are already being welcomed. Electrical installations made under 18th Edition guidelines are proven to be more eco-efficient. They have lessened their environmental impact and saved copious amounts of energy - and money - for public sector buildings. Mr Kenyon admits there have been some growing pains in administering all the 18th Edition regulations. However, he also believes that they are on the road to ‘best practice by achieving compliance’. It is his belief, and ours at Sparks too, that increased compliance with surge protection laws will improve electrical safety for years to come.

Introducing MK and Hager Amendment 3 Compliant Consumer Units at Sparks

After speaking of the 3rd Amendment to the 17th Edition Regs (which came into full application in the beginning of 2016), we need to pay attention to what kind of consumer units we install in new built properties, HMOs, or when we replace a consumer unit. The main considerations with these new boards is the protection against thermal effects (protection against fire) for a longer period of time and the protection against electrical shock (via an RCD). It used to be that the consumer units could use a plastic enclosure, but starting from the 1st of January 2016 ALL the consumer units installed have to be of metal and need to have an RCD protection. Most of the consumer unit manufacturers came out with a range of Metal Consumer Units (RCD protected, fireproof), and in this article, we would like to introduce some of the most popular ones from MK and Hager. MK 10 Way Metal Consumer Unit (Amendment 3 Compliant) - Best Value for Money! The MK Sentry K7666sMET consumer unit is a 17th Edition Amendment 3 compliant metal board, a 16-way enclosure with 10 useable ways. It comes fully populated with 10 MCBs (3 x 6A, 2 x 16A, 4 x 32A, 1 x 40A) and it has a 100A switch disconnector.This metal consumer unit has a stylish design, curved, and it makes full use of the floating bus bar system, offering you ample wiring space. This unit comes in a white colored metal and comes pre-fitted with a switch disconnector and RCD together with all the necessary split-load cabling. The flexible design allows you to position the RCD to suit the required configuration. At Sparks this MK board is now at a reduced price - it is the best Amendment 3 consumer unit value for money!Buy MK Consumer Units Hager Design 10 Consumer Units - Reliable and Supportive Hager came out with quite a few ranges of consumer units to comply with the third amendment to the 17th edition regulations, one of which is Hager Design 10. This range is designed for safety, installation, and aesthetics, and it is reliable and supportive. Here are some of the key points concerning these Amendment 3 compliant boards: Cable Space - Maximum cable space is available even with RCBOs fitted to make installation easier. Terminal bar - The top-mounted terminal rail makes the wiring of the neutral and earth connections neat and simple. Fixings - Multiple points allow the use of No.8 or No.10 fixings giving a range of fixing options. Full metal DIN rail - Minimised distortion to ensure the devices sit square and are not easily displaced. Snap-able busbar - Provides quick and easy configuration of circuits.Buy Hager Design 10 Consumer Units Enjoy a video presentation of this great range from Hager below:  See the entire range of Hager Design 10 - from 2-way to 20-way boards (all of them Amendment 3 Compliant and with 63A/100A switch disconnector incomer) at Sparks.

What are the Features and Benefits of the Hager Consumer Units?

We have noticed a video recently put online by Hager outlining the main features and benefits of their consumer units, and after watching the 1.07 min video we thought that our readers and customers would also benefit from watching it. We have spoken extensively about the Hager Domestic and Commercial Consumer units on our blog, but there's always something new and special that we find out about them.Update: the video has been made private by Hager, but the main benefits and features of these boards from Hager still stand Hager Consumer Units - Features and Benefits When we talk about the consumer units from Hager, we mean especially the domestic distribution boards. Take a look at this short video and don't forget to read the comments below.  Removable Top Wall - removes easily to provide cable access and re-seals to IP4X when used with the two foam strips provided. Cable Space - maximum cable space is available even with the RCBOs fitted so that the installation and the wiring would be much easier. The Terminal Bars - the top-mounted terminal rail makes the wiring of the neutral and earth connections easier and neater. Meter Tail Kit - an optional meter tail kit is available to make the wiring and termination on the incoming cables easier to install. Snap-able Busbar - a snap-able busbar provides a quick and simple configuration of the devices. You can purchase Hager Domestic Consumer Units via Sparks - or read more on our blog concerning these devices.Buy Hager Consumer Units at Sparks