The Evoges Guardian EG16W is a premium-quality 16 Way Consumer Unit designed to provide safe and reliable power distribution in domestic and light commercial electrical installations. Featuring a robust 18-way enclosure and a 100A double pole main switch, it receives the incoming electrical supply, provides main isolation, and distributes power to individual circuits throughout the property.

Designed for flexibility, the EG16W supports a wide range of circuit protection devices from the Evoges Guardian range, including MCBs, RCBOs, and AFDDs. This allows electricians to tailor protection levels to suit the installation, whether protecting lighting circuits, socket circuits, kitchen appliances, electric showers, or specialist equipment. The spacious enclosure provides ample wiring space, helping to simplify installation and future circuit additions.

Unlike SPD-equipped models, the EG16W is supplied without an integrated Surge Protection Device (SPD). This makes it an excellent choice for projects where surge protection is not required or where protection is being provided elsewhere within the installation. Manufactured to the latest British and European standards, the EG16W delivers dependable performance, regulatory compliance, and excellent value for professional electrical installations.

Technical Specifications

  • Manufacturer: Evoges
  • Range: Guardian
  • Product Code: EG16W
  • Product Type: Consumer Unit
  • Enclosure Size: 18 Way
  • Usable Outgoing Ways: 16 Way
  • Main Switch Rating: 100A Double Pole (DP)
  • Integrated SPD: No
  • Busbar Pins: 17
  • IP Rating: IP2XC
  • Consumer Unit Standard: BS EN 61439-3
  • Main Switch Standard: BS EN 60947-3
  • Compatible MCB Standard: BS EN IEC 60898-1
  • Compatible RCBO Standard: BS EN IEC 61009-1
  • Compatible AFDD Standard: BS EN 62606
  • Certification: UKCA
  • Certification: CE Marked
  • Height: 265mm
  • Width: 390mm
  • Depth: 123mm
  • Recommended Torque Settings
  • Main Switch: 35mm² maximum cable capacity, 3.5Nm torque
  • MCB: 16mm² maximum cable capacity, 2.0Nm torque
  • RCBO: 16mm² maximum cable capacity, 2.0Nm / 1.2Nm torque
  • Earth Terminals: 16mm² maximum cable capacity, 2.0Nm torque
  • Neutral Terminals: 16mm² maximum cable capacity, 2.0Nm torque

Who Needs This?

The Evoges Guardian EG16W is ideal for:

  • Qualified electricians carrying out new installations
  • Domestic property developers
  • Landlords upgrading electrical installations
  • Homeowners undertaking consumer unit replacements
  • Commercial property owners requiring reliable circuit distribution
  • Electrical contractors seeking a flexible consumer unit platform
  • With 16 outgoing ways available, this consumer unit is particularly suitable for medium to larger properties requiring multiple protected circuits, including lighting, sockets, kitchen appliances, electric showers, outdoor supplies, garages, EV charging circuits, and heating systems.

Who Can Install This?

In the UK, consumer units must only be installed, inspected, tested, and certified by a qualified electrician. Installation work must comply with the latest edition of BS 7671 (IET Wiring Regulations) and any applicable Building Regulations requirements. Proper testing and certification are essential to ensure the safety and compliance of the electrical installation.

Consumer Units FAQ

What is a consumer unit?

A consumer unit, often referred to as a fuse box, is the main electrical distribution board within a property. It receives power from the electricity supply and safely distributes it to individual circuits while housing protective devices such as MCBs, RCBOs, and AFDDs.

Does this consumer unit include surge protection?

No. The Evoges Guardian EG16W does not include an integrated Surge Protection Device (SPD). If surge protection is required, an SPD-equipped consumer unit or separate surge protection solution should be considered.

What protective devices can be installed in this consumer unit?

The EG16W is designed for use with Evoges Guardian protective devices, including MCBs, RCBOs, AFDD RCBOs, and surge protection modules where applicable.

How many circuits can this consumer unit accommodate?

The EG16W provides 16 usable outgoing ways, making it suitable for installations requiring multiple individual circuits and dedicated protection devices.

Why Customers Love and Recommend This Consumer Unit

  • Large 16-way capacity suitable for modern homes and commercial premises
  • Strong steel enclosure with professional finish
  • 100A double pole main switch for reliable isolation
  • Compatible with Guardian MCBs, RCBOs, and AFDDs
  • Spacious internal design for easier wiring and installation
  • Manufactured to current British and European standards
  • UKCA and CE certified
  • Excellent value compared to many premium consumer unit brands
  • Flexible configuration for a wide range of installation requirements
  • Designed specifically for modern electrical installations

What Else Do I Need With This Consumer Unit?

To complete your installation, you will typically require protective devices from the Evoges Guardian range:

Guardian MCBs

For overload and short-circuit protection on individual circuits:

  • EGM06B6A – 6A MCB (lighting circuits)
  • EGM06B10A – 10A MCB
  • EGM06B16A – 16A MCB
  • EGM06B20A – 20A MCB
  • EGM06B32A – 32A MCB
  • EGM06B40A – 40A MCB
  • EGM06B50A – 50A MCB
  • EGM06B63A – 63A MCB

Guardian RCBOs

For overload, short-circuit, and residual current protection on individual circuits:

  • EGRB6A30 – 6A RCBO
  • EGRB10A30 – 10A RCBO
  • EGRB16A30 – 16A RCBO
  • EGRB20A30 – 20A RCBO
  • EGRB32A30 – 32A RCBO
  • EGRB40A30 – 40A RCBO

Guardian AFDD RCBOs

For enhanced fire protection and arc fault detection:

  • EGAFDD06B32A30 – 32A AFDD RCBO

Your electrician will determine the correct combination of MCBs, RCBOs, and AFDDs based on the circuit design, load requirements, and current BS 7671 wiring regulations.

Note: Some images and pictures are for reference only. The item may differ from the image/picture due to manufacturer's change. Should you require the exact item in the picture, please call or email us to enquire.

Ask a question

Note: HTML is not translated!

Shipping

Sparks Direct delivers via courier to the UK only; the standard delivery charge is £6 + VAT for all orders under £100 + VAT. If your order is over £120, you get free delivery (unless there's a special delivery charge for the items you wish to order or you're in shipping zone C or D). Full details for shipping charges can be found via Terms and Conditions.

If the items you order are in stock and the order is placed before 1.00pm, delivery can be made within 1-2 working days. If the items are not in stock, we will inform you via email how long it will take or ask for your confirmation if there's a long lead time.

Returns

We offer 30-day returns for unwanted items - please email us to request a returns number which will need to be quoted when the items are returned. For faulty items or items damaged in transit, please advise via email, and an appropriate returns number will be provided. Full details concerning returns and refunds can be found via our Terms and Conditions.

More from This Range

View the Evoges Full Range