Guardian EGAFDD06B32A30 32A AFDD RCBO 30mA 6kA Type A B Curve 1P+N Arc Fault Detection Device for Guardian Consumer Units
£60.00
Ex. VAT(over £100+VAT, applies to zone A only , £6 +VAT otherwise)
Order online & collect in store
The Evoges Guardian EGAFDD06B32A30 is an advanced Arc Fault Detection Device (AFDD) with integrated RCBO protection, providing a comprehensive solution for modern electrical installations. Designed for use within Evoges Guardian consumer units, it combines arc fault detection, overload protection, short-circuit protection, and residual current protection in a single device, helping to reduce the risk of electrical fires caused by dangerous arc faults.
With a 32A current rating, 30mA residual current sensitivity, and 6kA breaking capacity, this AFDD RCBO offers enhanced protection for socket circuits, ring finals, and other power circuits commonly found in residential and light commercial environments. The integrated AFDD technology continuously monitors the electrical circuit and can detect potentially hazardous series and parallel arc faults that conventional protective devices may not identify.
Manufactured to BS EN IEC 61009-1 and BS EN IEC 62606 standards, the EGAFDD06B32A30 is designed to meet the latest safety requirements and recommendations within modern electrical installations. It provides electricians and property owners with an additional layer of protection where fire prevention and enhanced electrical safety are a priority.
Technical Specifications
- Manufacturer: Evoges
- Range: Guardian
- Product Code: EGAFDD06B32A30
- Device Type: AFDD RCBO (Arc Fault Detection Device with RCBO Protection)
- Current Rating: 32A
- Tripping Sensitivity: 30mA
- Breaking Capacity: 6kA
- Curve Type: B Curve
- Residual Current Type: Type A
- Poles: 1P+N (Single Pole + Neutral)
- Arc Fault Detection: Yes
- Rated Voltage: 230-240V AC
- Frequency: 50/60Hz
- Standard: BS EN IEC 61009-1
- Standard: BS EN IEC 62606
- Ingress Protection Rating: IP20
- Certification: UKCA
- Certification: CE Marked
- ECP Reference: ECP202510
- Application: Enhanced circuit and fire protection within Evoges Guardian Consumer Units
Who Needs This?
The Evoges Guardian EGAFDD06B32A30 is ideal for electricians, developers, landlords, housing associations, commercial property owners, and homeowners seeking enhanced protection against electrical fires. It is particularly suitable for protecting ring final circuits, socket outlet circuits, and areas where increased fire safety is recommended.
AFDDs are increasingly specified in higher-risk environments such as:
- Residential dwellings
- Houses in Multiple Occupation (HMOs)
- Student accommodation
- Care homes
- Residential timber-framed buildings
- Sleeping accommodation
- Commercial premises requiring enhanced fire protection
Please note: This AFDD RCBO is designed specifically for use with Evoges Guardian Consumer Units. The consumer unit must be purchased separately.
Who Can Install This?
In the UK, AFDDs and consumer unit protective devices should only be installed by a qualified electrician. Installation must comply with the latest edition of BS 7671 (IET Wiring Regulations), including inspection, testing, and certification to ensure a safe and compliant electrical installation.
Consumer Units FAQ
What is an AFDD?
An AFDD (Arc Fault Detection Device) is a protective device designed to detect dangerous electrical arc faults that may lead to overheating and electrical fires. When an arc fault is detected, the device automatically disconnects the circuit.
How is an AFDD different from an RCBO?
An RCBO protects against overloads, short circuits, and earth leakage faults. An AFDD RCBO provides all of these protections while also detecting potentially dangerous arc faults that traditional devices may not identify.
Where are AFDDs commonly installed?
AFDDs are commonly installed on socket circuits, ring final circuits, and in buildings where enhanced fire protection is recommended, such as homes, HMOs, care facilities, student accommodation, and timber-framed buildings.
Is this AFDD compatible with all consumer units?
No. The Evoges Guardian EGAFDD06B32A30 has been specifically designed for use within Evoges Guardian Consumer Units and should only be installed in compatible boards.
| Consumer Units | |
| Amperage Rating | 32A |
| Compliance | BS EN IEC 60898-1 |
| Domestic/Industrial | Domestic |
| IP rating | IP20 |
| Manufacturer | Evoges |
| Mounting | In the Consumer Unit |
| Range | Evoges Guardian |
| RCD included | no |
Note: Some images and pictures are for reference only. The item may differ from the image/picture due to manufacturer's change. Should you require the exact item in the picture, please call or email us to enquire.
Shipping
Sparks Direct delivers via courier to the UK only; the standard delivery charge is £6 + VAT for all orders under £100 + VAT. If your order is over £120, you get free delivery (unless there's a special delivery charge for the items you wish to order or you're in shipping zone C or D). Full details for shipping charges can be found via Terms and Conditions.
If the items you order are in stock and the order is placed before 1.00pm, delivery can be made within 1-2 working days. If the items are not in stock, we will inform you via email how long it will take or ask for your confirmation if there's a long lead time.
Returns
We offer 30-day returns for unwanted items - please email us to request a returns number which will need to be quoted when the items are returned. For faulty items or items damaged in transit, please advise via email, and an appropriate returns number will be provided. Full details concerning returns and refunds can be found via our Terms and Conditions.