Quickwire Switch and Load Junction Box IP30 16A for Two Power Connections 1.0-1.5mm2 Twin & Earth

Model No. QSL34
£3.40 Ex. VAT
This item requires:

Free delivery
(over £100 +VAT, applies to zone A and B only, £6 +VAT otherwise)

Normally In Stock

Click & Collect

Order online & collect in store

Our customers love us - read their reviews

Wishlist Ask a question Compare

The Quickwire Switch & Load usually does a single lighting circuit spur, that is, one light wired off the main circuit; if you need to add more lights, you will also need the Quickwire Splitter. 

Switch & Load Junction Box - Specs

  • Rating: rated at 16A 250Va.c., and Overcurrent protection limited to 16A
  • Standards: BS EN 60670-22, BS 5733-MF
  • Conductor Size: 1.0mm² – 1.5mm² Twin & Earth (CPC) Solid cores, Class 1 (conductors)
  • Dimensions: 23mm x 31mm x 84mm (cable entries inserted)
  • IP Rating: IP30 rated
  • Small and compact size, ideal to fit into small ceiling voids and tight spaces.
  • Easy to use: no screws, no clips, no clamps, and no cover! No fuss!
  • it comes pre-wired, and it is clearly labeled for error-free wiring. 
  • Maintenance free: with screwless push-fit terminals for use in inaccessible places. 
  • It has a compact design, small enough to fit through a 32mm diameter hole. 
  • The cable can be clipped into place and installed in a matter of seconds. There's no need to sheath the earth. Less materials and less time and less tools. 
  • Cable preparation: Cut and strip the 1.0mm² / 1.5mm² solid core, flat twin and earth cable.
  • If required the Quickwire can be fitted onto a surface using the Quickwire mounting clip (order separately). 
  • Warning: Do not cover

How to use: steps (matching the pictures)

  • Step One - Orientate and align pre-cut cable and insert into appropriate cable entry point. Each wire should guide itself into the correct terminal. Push cable until there is resistance.
  • Step Two - Check there is a sufficient length of outer cable sheath available for clamping (fig.1) and that an unbroken length of conductor occupies the full extent of the window (fig.2).
  • Step Three - Push cable until it snaps into place. Repeat process for additional cables. Push in any unused cable entries.

 

Follow us for exclusive offers and tips about lighting, switches and sockets

Get in touch

Telephone 020 7263 8007

Fax 020 7272 3007

Sparks Electrical Wholesalers Ltd, 659-661 Holloway Road, Archway, London, N19 5SE, United Kingdom
Registered in England. Company No. 2238028. VAT Reg No: GB 505 6899 17. Copyright © 2003-2019 SparksDirect

Award Winning Ecommerce from Cyber-Duck