All the electrical installations will deteriorate with age and with use.

They should therefore be inspected and tested at appropriate intervals of time in order to check whether they are in a satisfactory condition for continued service.

Such safety checks are commonly referred to as "Periodic Inspection and Testing". A periodic inspection and test accomplishes the following:

  • It will reveal if any of your electrical circuits or equipment are overloaded.
  • This test will find any potential electric shock risks and fire hazards.
  • It will identify any defective electrical work.
  • This test will highlight any lack of earthing or bonding.
Such periodical tests are also carried out on the wiring and fixed electrical equipment to check that they are safe.

A schedule of circuits is also provided, which is invaluable for a property.

How often is a periodic inspection required? Depending on what kind of a property / home you have, your electrics should be inspected and tested every:

  • 10 years for an owner-occupied home.
  • 5 years for a rented home.
  • 3 years for a caravan
  • 1 year for a swimming pool.
Also, a periodic inspection needs to be carried out whenever a property is being prepared for letting, or before selling a property / buying a previously-occupied property.

Who should carry out the periodic inspection and what happens?

The periodic inspection and testing should be carried out only by electrically competent persons, such as registered electricians. They will check the condition of the electrics against the UK standard for the safety of electrical installations, BS 7671 – Requirements for Electrical Installations (IEE Wiring Regulations). The inspection takes into account all the relevant circumstances and checks on:

  • The adequacy of earthing and bonding.
  • The suitability of the switchgear and control gear. For example, an old fusebox with a wooden back, cast-iron switches, or a mixture of both will need replacing.
  • The serviceability of switches, sockets and lighting fittings. Items that may need replacing include: older round-pin sockets, round light switches, cables with fabric coating hanging from ceiling roses to light fittings, black switches and sockets mounted in skirting boards.
  • The type of wiring system and its condition. For example, cables coated in black rubber were phased out in the 1960s. Likewise cables coated in lead or fabric are even older and may well need replacing (modern cables use longer-lasting pvc insulation).
  • Sockets that may be used to supply portable electrical equipment for use outdoors, making sure they are protected by a suitable residual current device (RCD).
  • The presence of adequate identification and notices.
  • The extent of any wear and tear, damage or other deterioration.
  • Any changes in the use of the premises that have led to, or may lead to, unsafe conditions.
The competent person will then issue an Electrical Installation Condition Report detailing any observed damage, deterioration, defects, dangerous conditions and any non-compliances with the present-day safety standard that might give rise to danger.

If any dangerous or potentially dangerous condition or conditions are found, the overall condition of the electrical installation will be declared to be 'unsatisfactory', meaning that remedial action is required without delay to remove the risks to those in the premises.

Continue reading this explanation with more materials to download at, The Electrical Safety Council - the Periodic Inspection Explained - or read more about Electrical Safety and Energy Saving.